Acceptable Solution E2/AS1: External Moisture

This resource is no longer current. E2/AS1 (Amd 10) (Third Edition, Amendment 10),

Abbreviation
E2/AS1 (Amd 7)
Version
Third Edition, Amendment 7
Valid to
31/03/2019
Valid from
1/01/2017

Information provider
Ministry of Business, Innovation and Employment,
Information type
Acceptable Solution,
Format
PDF,


Description

Acceptable Solution E2/AS1 provides a means of compliance with Building Code Clause E2 External Moisture.

Building Code Clause E2 requires external roof, wall claddings and external openings to prevent external moisture from causing undue dampness or damage.

It requires buildings to be constructed to provide adequate resistance to penetration by, and the accumulation of, moisture from the outside. It contains requirements for roofs, wall claddings and external openings to: prevent water entry; prevent water absorption and transmission; prevent the accumulation of water; and allow for dissipation.

This Acceptable Solution coves the weathertightness of the building envelope.

Scope

The scope of this Acceptable Solution is limited to the materials, products and processes contained herein, for buildings within the scope of NZS 3604, and:

  • a) Up to 3 storeys with a height measured from lowest ground level adjacent to the building to the highest point of the roof (except for chimneys, aerials and the like) of 10 m or less, and
  • b) With floor plan area limited only by seismic and structural control joints, and
  • c) External walls that are vertical, and roofs that are 60 or less above the horizontal. Where buildings are based on NZS 3604, but require specific engineering design input, the framing shall be of at least equivalent stiffness to the framing provisions of NZS 3604.
This resource is not cited by any other resources.

Acceptable Solution E2/AS1: External Moisture

This document is not CITED BY any other resources:

Acceptable Solution E2/AS1: External Moisture

Description

Acceptable Solution E2/AS1 provides a means of compliance with Building Code Clause E2 External Moisture.

Building Code Clause E2 requires external roof, wall claddings and external openings to prevent external moisture from causing undue dampness or damage.

It requires buildings to be constructed to provide adequate resistance to penetration by, and the accumulation of, moisture from the outside. It contains requirements for roofs, wall claddings and external openings to: prevent water entry; prevent water absorption and transmission; prevent the accumulation of water; and allow for dissipation.

This Acceptable Solution coves the weathertightness of the building envelope.

View on Information Provider website Download this resource (PDF, 14.4MB)
Acceptable Solution E2/AS1: External Moisture

This resource is no longer current. E2/AS1 (Amd 10) (Third Edition, Amendment 10),

Description

Acceptable Solution E2/AS1 provides a means of compliance with Building Code Clause E2 External Moisture.

Building Code Clause E2 requires external roof, wall claddings and external openings to prevent external moisture from causing undue dampness or damage.

It requires buildings to be constructed to provide adequate resistance to penetration by, and the accumulation of, moisture from the outside. It contains requirements for roofs, wall claddings and external openings to: prevent water entry; prevent water absorption and transmission; prevent the accumulation of water; and allow for dissipation.

This Acceptable Solution coves the weathertightness of the building envelope.

View on Information Provider website Download this resource (PDF, 14.4MB)
This resource cites:

Acceptable Solution E2/AS1: External Moisture

This document CITES:
Feedback