AS 4032.4:2014 Water supply - Valves for the control of heated water supply temperatures. Part 4: Thermostatically controlled taps for the control of heated water supply temperatures

Abbreviation
AS 4032.4:2014
Valid from
11/06/2014

Information provider
Intertek Inform,
Author
Standards Australia
Information type
Australian Standard,
Format
PDF, HARD COPY,


Description

This Standard specifies requirements for the design, construction, testing performance and means of compliance for thermostatic mixing taps—

  • a) for use with heated water at a supply temperature not exceeding 90°C; 
  • b) for use with hot and cold water with working pressures not exceeding 1400 kPa; and
  • c) of nominal sizes not larger than DN 20.

When used for ablutionary purposes, thermostatic mixing taps complying with this Standard provide the user with reasonable protection against scalding or excessive temperature fluctuations due to variations of pressures and temperatures of the hot and cold water supplies, including thermal shut-off.

Scope

NOTES: 

  1. Diagrams in this Standard are typical.
  2. This Standard includes a method for assessing the flow performance of a thermostatic mixing tap but at the time of its publication, the Standard is not referenced in AS/NZS 6400.
For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

AS 4032.4:2014 Water supply - Valves for the control of heated water supply temperatures. Part 4: Thermostatically controlled taps for the control of heated water supply temperatures

This document is CITED BY:

AS 4032.4:2014 Water supply - Valves for the control of heated water supply temperatures. Part 4: Thermostatically controlled taps for the control of heated water supply temperatures

Description

This Standard specifies requirements for the design, construction, testing performance and means of compliance for thermostatic mixing taps—

  • a) for use with heated water at a supply temperature not exceeding 90°C; 
  • b) for use with hot and cold water with working pressures not exceeding 1400 kPa; and
  • c) of nominal sizes not larger than DN 20.

When used for ablutionary purposes, thermostatic mixing taps complying with this Standard provide the user with reasonable protection against scalding or excessive temperature fluctuations due to variations of pressures and temperatures of the hot and cold water supplies, including thermal shut-off.

View on Information Provider website
AS 4032.4:2014 Water supply - Valves for the control of heated water supply temperatures. Part 4: Thermostatically controlled taps for the control of heated water supply temperatures
Description

This Standard specifies requirements for the design, construction, testing performance and means of compliance for thermostatic mixing taps—

  • a) for use with heated water at a supply temperature not exceeding 90°C; 
  • b) for use with hot and cold water with working pressures not exceeding 1400 kPa; and
  • c) of nominal sizes not larger than DN 20.

When used for ablutionary purposes, thermostatic mixing taps complying with this Standard provide the user with reasonable protection against scalding or excessive temperature fluctuations due to variations of pressures and temperatures of the hot and cold water supplies, including thermal shut-off.