Acceptable Solution C/AS2: Buildings other than Risk Group SH
- Abbreviation
- C/AS2 (First Edition, Amd 1 (Errata 1)
- Amendment
- 1
- Version
- First Edition, Amendment 1 (Errata1 - 22/10/2019)
- Valid to
- 3/11/2021
- Valid from
- 27/06/2019
This resource is no longer current.
- Information provider
- Ministry of Business, Innovation and Employment,
- Information type
- Acceptable Solution,
- Format
- PDF,
Description
The Building Code clauses C1 to C6 Protection from Fire relate to:
- a) safeguard people from an unacceptable risk of injury or illness caused by fire,
- b) protect other property from damage caused by fire, and
- c) facilitate firefighting and rescue operations.
This Acceptable Solution C/AS2 is one of three Acceptable Solutions that provide a means of establishing compliance with NZBC Clauses C1 to C6 Protection from Fire. It can be used for the building activities covered by risk groups specified in Paragraph 1.1.1 and described in Table 1.1.
For risk group SH, please refer to Acceptable Solution C/AS1.
For backcountry huts, please refer to Acceptable Solution BCH/AS1.
Where a specific risk group (or risk groups) is mentioned in a subheading and/or within the text of a paragraph, that requirement applies only to the specified risk group(s), and does not apply to other risk groups. Words in italic are defined at the front of this document.
Appendices to this Acceptable Solution are part of, and have equal status to, the Acceptable Solution.
Figures and risk group icons are informative only; the wording of the paragraphs takes precedence.
Scope
The scope of this Acceptable Solution C/AS2 is restricted to all risk groups listed in Table 1.1 except for risk group SH (refer to C/AS1).
It covers buildings or parts of buildings where people:
- a) Sleep (SM), and
- b) Are unable to self-evacuate without assistance through requiring special care or treatment, or they are restrained, or their liberties are restricted (SI), and
- c) Congregate, participate in group activities or where professional services or retail are provided (CA), and
- d) Work (WB), and
- e) Store goods and other materials (WS), and
- f) Park vehicles (VP).
These activities are described in Table 1.1.
This resource is not cited by any other resources.
Acceptable Solution C/AS2: Buildings other than Risk Group SH
This document is not CITED BY any other resources:
This resource cites:
Acceptable Solution C/AS2: Buildings other than Risk Group SH
This document CITES:
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS/NZS 1668.1:1998 The use of ventilation and air conditioning in buildings - Fire and smoke control in multi-compartment buildings from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS/NZS 2918:2001 Domestic solid fuel burning appliances - Installation from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS/NZS 3837:1998 (R216) Method of test for heat and smoke release rates for materials and products using an oxygen consumption calorimeter from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS/NZS 5601.1:2010 Gas installations - Part 1: General installations from 27/06/2019 until 3/11/2021
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS/NZS 60598.2.2:2001 Luminaires - Particular requirements - Recessed luminaires from 27/06/2019 until 3/11/2021
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4232.2:1988 Performance criteria for fire resisting enclosures - Fire resisting glazing systems - SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4332:1997 Non-domestic passenger and goods lifts - SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4510:2008 Fire hydrant systems for buildings - SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4512:2010 Fire detection and alarm systems in buildings -SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4515:2009 Fire sprinkler systems for life safety in sleeping occupancies (up to 2000 square metres) - SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4520:2010 Fire resistant doorsets - SPONSORED from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS 4541:2013 Automatic fire sprinkler systems from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS/AS 1530.1:1994 (R2016) Methods for fire tests on building materials, components and structures - Part 1: Combustibility test for materials from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS/BS 476.21:1987 Fire tests on building materials and structures - Methods for determination of the fire resistance of loadbearing elements of construction from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1366.1-1992 (R2018) Rigid cellular plastics sheets for thermal insulation - Rigid cellular polyurethane (RC/PUR) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1366.2-1992 (R2018) Rigid cellular plastics sheets for thermal insulation - Rigid cellular polyisocyanurate (RC/PIR) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1366.3-1992 (R2018) Rigid cellular plastics sheets for thermal insulation - Rigid cellular polystyrene - moulded (RC/PS-M) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1366.4-1989 (R2018) Rigid cellular plastics sheets for thermal insulation - Rigid cellular polystyrene - extruded (RC/PS-E) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1530.2-1993 (R2016) Methods for fire tests on building materials, components and structures. Part 2: Test for flammability of materials from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1530.4-2005 Methods for fire tests on building materials, components and structures. Part 4: Fire-resistance test of elements of construction from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1682.1-1990 Fire dampers - Part 1: Specification from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1682.2-1990 Fire dampers - Part 2: Installation from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 1691-1985 Domestic oil-fired appliances - installation from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 4072.1-2005 (R2016) Components for the protection of openings in fire-resistant separating elements. Part 1: Service penetrations and control joints from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 4254.1-2012 Ductwork for air-handling systems in buildings. Part 1: Flexible duct from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS 4254.2-2012 Ductwork for air-handling systems in buildings. Part 2: Rigid duct from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites AS ISO 9705-2003 (R2016) Fire tests - Full-scale room test for surface products from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites ASTM D2898-10 Standard Practice for Accelerated Weathering of Fire-retardant Treated Wood for Fire Testing from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites BS EN 12101-1:2005 Smoke and heat control systems - Specification for smoke barriers from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites BS EN 13501-1:2007 Fire classification of construction products and building elements - Classification using test data from reaction to fire tests from 27/06/2019 until 3/11/2021
C/AS2 (First Edition, Amd 1 (Errata 1) cites Hazardous Substances and New Organisms Act 1996 from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites ISO 5660-1:2002 Reaction-to-fire tests - Heat release, smoke production and mass loss rate - Heat release rate (cone calorimeter method) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites ISO 5660-2:2002 Reaction-to-fire tests - Heat release, smoke production and mass loss rate - Smoke production rate (dynamic measurement) from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites ISO 9239-1:2010 Reaction to fire tests for floorings - Determination of the burning behaviour using a radiant heat source from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites ISO 9705:1993 Fire tests - Full scale room test for surface products from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites Health and Safety at Work (Hazardous Substances) Regulations 2017 from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NCC 2015 - National Construction Code of Australia - Complete Series from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites NFPA 285:2012 Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components from 27/06/2019 until 3/11/2021
C/AS2 (First Edition, Amd 1 (Errata 1) cites NZS/BS 476.22:1987 Fire tests on building materials and structures. Method for determination of the fire resistance of non-loadbearing elements of construction from 27/06/2019
C/AS2 (First Edition, Amd 1 (Errata 1) cites Education (Early Childhood Services) Regulations 2008 from 27/06/2019