Acceptable Solution B1/AS1: General
- Abbreviation
- B1/AS1 (Amd 16)
- Amendment
- 16
- Version
- First edition, Amendment 16
- Valid to
- 31/03/2019
- Valid from
- 3/04/2018
This resource is no longer current. B1/AS1 (Amd 21) (First Edition, Amendment 21),
- Information provider
- Ministry of Business, Innovation and Employment,
- Information type
- Acceptable Solution,
- Format
- PDF,
Description
Acceptable Solution B1/AS1 provides a means of compliance with Building Code Clause B1 Structure. Clause B1 requires buildings to withstand likely loads, including wind, earthquake, live and dead loads (people and building contents).
It makes due allowance for the intended use of a building, the consequence of failure and other limitations. B1/AS1 contains Acceptable Solutions for:
- Masonry
- Timber
- Earth Buildings
- Stucco
- Drains
- Glazing
Scope
The citation covers only the scope stated or implicit in each Standard. Aspects outside the scope, when applied to a particular building, are not part of the Verification Method.
This resource is not cited by any other resources.
Acceptable Solution B1/AS1: General
This document is not CITED BY any other resources:
This resource cites:
Acceptable Solution B1/AS1: General
This document CITES:
B1/AS1 (Amd 16) cites AS/NZS 1170.0:2002 Structural Design Actions - General principles from 1/12/2008
B1/AS1 (Amd 16) cites AS/NZS 1170.1:2002 (R2016) Structural Design Actions - Permanent, imposed and other actions from 1/12/2008
B1/AS1 (Amd 16) cites AS/NZS 1170.2:2011 (R2016) Structural Design Actions - Wind Actions from 14/02/2014
B1/AS1 (Amd 16) cites AS/NZS 1170.3:2003 (R2016) Structural Design Actions - Snow and ice actions from 1/12/2008
B1/AS1 (Amd 16) cites AS/NZS 2032:2006 Installation of PVC pipe systems from 30/09/2010
B1/AS1 (Amd 16) cites AS/NZS 2033:2008 Installation of polyethylene pipe systems from 30/09/2010
B1/AS1 (Amd 16) cites AS/NZS 2566.1:1998 (R2018) Buried Flexible pipelines. Structural Design from 30/09/2010
B1/AS1 (Amd 16) cites AS/NZS 2566.2:2002 (R2016) Buried Flexible pipelines - Installation from 30/09/2010
B1/AS1 (Amd 16) cites AS/NZS 4671:2001 Steel reinforcing materials from 30/09/2010
B1/AS1 (Amd 16) cites NZS 3604:2011 Timber-framed buildings - SPONSORED from 19/05/2011
B1/AS1 (Amd 16) cites NZS 4223.1:2008 Code of practice for glazing in buildings - Glass selection and glazing - SPONSORED from 30/09/2010
B1/AS1 (Amd 16) cites NZS 4223.2:2016 Glazing in buildings Part 2: Insulating glass units - SPONSORED from 1/06/2016
B1/AS1 (Amd 16) cites NZS 4223.3:2016 Glazing in buildings - Human impact safety requirements - SPONSORED from 1/06/2016
B1/AS1 (Amd 16) cites NZS 4223.4:2008 Code of practice for glazing in buildings - Wind, dead, snow, and live actions - SPONSORED from 30/09/2010
B1/AS1 (Amd 16) cites NZS 4229:2013 Concrete masonry buildings not requiring specific engineering design - SPONSORED from 14/12/2014
B1/AS1 (Amd 16) cites NZS 4251.1:2007 Solid plastering - Cement plaster for walls, ceilings and soffits - SPONSORED from 1/08/2011
B1/AS1 (Amd 16) cites NZS 4299:1998 Earth buildings not requiring specific design - SPONSORED from 1/12/2000