Verification Method H1/VM1: Energy efficiency for all housing, and buildings up to 300 m².
- Abbreviation
- H1/VM1 (Fifth edition, Amd 1)
- Amendment
- 1
- Version
- Fifth edition, Amendment 1
- Valid from
- 4/08/2022
- Information provider
- Ministry of Business, Innovation and Employment,
- Information type
- Verification Method,
- Format
- PDF,
Description
Verification Method H1/VM1 provides a means of compliance with Building Code Clause H1 Energy Efficiency.
Verification Method H1/VM1 applies to:
- a) housing; and
- b) other buildings with a floor area of occupied space no greater than 300 m², that are communal residential, communal non-residential (assembly care only) and commercial buildings.
For buildings that do not meet these characteristics, refer to the Acceptable Solution H1/AS2 or Verification Method H1/VM2 as a means to demonstrate compliance or use an alternative means to demonstrate compliance.
Scope
The Verification Method H1/VM1 does not include:
- the use of foil insulation,
- requirements to comply with Building Code clauses H.1.3.1(b), H1.3.4, H1.3.5 or H1.3.6. For these clauses, use an alternative means to demonstrate compliance.
This resource is not cited by any other resources.
Verification Method H1/VM1: Energy efficiency for all housing, and buildings up to 300 m².
This document is not CITED BY any other resources:
This resource cites:
Verification Method H1/VM1: Energy efficiency for all housing, and buildings up to 300 m².
This document CITES:
H1/VM1 (Fifth edition, Amd 1) cites AS/NZS 4859.1:2018 Thermal insulation materials for buildings, Part 1: General criteria and technical provisions from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites NZS 4214:2006 Methods of determining the total thermal resistance of parts of buildings - SPONSORED from 31/10/2007
H1/VM1 (Fifth edition, Amd 1) cites NZS 4303:1990 Ventilation for acceptable indoor air quality - SPONSORED from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 13370:2017 Thermal performance of buildings - Heat transfer via the ground - Calculation methods from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ANSI/ASHRAE 140-2017 Standard Method Of Test For The Evaluation Of Building Energy Analysis Computer Programs from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites BRANZ House Insulation Guide, 5th Edition 2014 from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites BS EN 673:2011 Glass in building. Determination of thermal transmittance (U value). Calculation method from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 10077-2:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 10211:2017 Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 10456:2007 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 12631:2017 Thermal performance of curtain walling — Calculation of thermal transmittance from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites ISO 13789:2017 Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites International Energy Agency Building Energy Simulation Test (BESTEST) and Diagnostic Method from 29/11/2021
H1/VM1 (Fifth edition, Amd 1) cites Temperature normals for New Zealand for the period 1961 - 1990 from 31/10/2007