AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) - Wind loads
- Abbreviation
- AS 1170.2-1989
- Amendment
- AS 1170.2-1989/Amdt 1-1991 AS 1170.2-1989/Amdt 2-1993 AS 1170.2-1989/Amdt 3-1993
- Valid from
- 20/03/1989
- Information provider
- Intertek Inform,
- Information type
- Australian Standard,
- Format
- PDF, HARD COPY,
Description
This Standard sets out requirements for establishing the minimum wind loads in structural design, and is in a limit states format. It provides a simplified procedure for the determination of wind loads on a limited range of small structures and buildings, and a detailed procedure on a wide range of structures.
Windspeeds are specified for the serviceability and ultimate strength/stability limit states, and for permissible stress design. Explanatory material is given in the appendices.
Scope
This Standard sets out procedures for determining design wind speeds and wind loads to be used in structural design of all buildings and components of buildings, bridges (minimum design wind speed only), and other structures subjected to wind.
For bridges, the design wind loads shall be determined in accordance with the AUSTROADS Bridge Design Code.
Major offshore structures remote from the coast and transmission lines are not covered, nor are the effects of tornadoes which are special-event winds.
The design wind loads for structures containing high risk contaminants, such as some nuclear or biological materials is considered outside the scope of this Standard.
This Standard does not attempt to account for possible future climatic changes.
This resource is cited by:
AS 1170.2-1989 Minimum design loads on structures (known as the SAA Loading Code) - Wind loads
This document is CITED BY:
-
AS 2049-2002 (R2015)
AS 1170.2-1989 is cited by AS 2049-2002 (R2015) Roof tiles
-
AS 2159-1995
AS 1170.2-1989 is cited by AS 2159-1995 Rules for the design and installation of piling (known as the SAA Piling Code)
-
AS/NZS 1664.1:1997
AS 1170.2-1989 is cited by AS/NZS 1664.1:1997 Aluminium structures - Limit state design
-
AS/NZS 2699.2:2000
AS 1170.2-1989 is cited by AS/NZS 2699.2:2000 Built-in components for masonry construction - Connectors and accessories
-
AS/NZS 4200.1:1994
AS 1170.2-1989 is cited by AS/NZS 4200.1:1994 Pliable building membranes and underlays - Materials
-
NZS 4203:1992
AS 1170.2-1989 is cited by NZS 4203:1992 General structural design and design loadings for buildings - SPONSORED