BS EN 12285-2:2005 Workshop fabricated steel tanks - Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids

Abbreviation
BS EN 12285-2:2005
Valid from
21/02/2005

Information provider
Standards New Zealand
Author
British Standards Institution
Information type
British Standard


Description

BS EN 12285-2:2005 specifies the requirements for metallic shop fabricated cylindrical, horizontal steel tanks, single and double skin for the aboveground storage of water polluting liquids (both flammable and non-flammable) within the following limits:

  • from 800 mm up to 3000 mm nominal diameter
  • up to a maximum overall length of 6 times the nominal diameter
  • for liquids with a maximum density of up to 1.9 kg/l with an operating pressure of maximum 1.5 bar (abs.)
  • where double skin tanks with a vacuum leak detection system are used the cinematic viscosity of the stored media shall not exceed 0.005 m2/s.

This standard is applicable for normal ambient temperature conditions (-20 degrees C to + 50 degrees C).

This standard is not applicable to the storage of dangerous liquids such as explosives, substances liable to spontaneous combustion, substances which in contact with water emit flammable gases, organic peroxides, infectious substances, radioactive material, hydrocyanic or hydrocyanic solvent liquids, metalcarbonyls, hydrofluoracid and bromide liquids.

This standard does not cover the installation of tanks which might be subject to local regulations involving pollution control.

 

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

BS EN 12285-2:2005 Workshop fabricated steel tanks - Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids

This document is CITED BY:

BS EN 12285-2:2005 Workshop fabricated steel tanks - Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids

Description

BS EN 12285-2:2005 specifies the requirements for metallic shop fabricated cylindrical, horizontal steel tanks, single and double skin for the aboveground storage of water polluting liquids (both flammable and non-flammable) within the following limits:

  • from 800 mm up to 3000 mm nominal diameter
  • up to a maximum overall length of 6 times the nominal diameter
  • for liquids with a maximum density of up to 1.9 kg/l with an operating pressure of maximum 1.5 bar (abs.)
  • where double skin tanks with a vacuum leak detection system are used the cinematic viscosity of the stored media shall not exceed 0.005 m2/s.

This standard is applicable for normal ambient temperature conditions (-20 degrees C to + 50 degrees C).

This standard is not applicable to the storage of dangerous liquids such as explosives, substances liable to spontaneous combustion, substances which in contact with water emit flammable gases, organic peroxides, infectious substances, radioactive material, hydrocyanic or hydrocyanic solvent liquids, metalcarbonyls, hydrofluoracid and bromide liquids.

This standard does not cover the installation of tanks which might be subject to local regulations involving pollution control.

 

View on Information Provider website
BS EN 12285-2:2005 Workshop fabricated steel tanks - Horizontal cylindrical single skin and double skin tanks for the aboveground storage of flammable and non-flammable water polluting liquids
Description

BS EN 12285-2:2005 specifies the requirements for metallic shop fabricated cylindrical, horizontal steel tanks, single and double skin for the aboveground storage of water polluting liquids (both flammable and non-flammable) within the following limits:

  • from 800 mm up to 3000 mm nominal diameter
  • up to a maximum overall length of 6 times the nominal diameter
  • for liquids with a maximum density of up to 1.9 kg/l with an operating pressure of maximum 1.5 bar (abs.)
  • where double skin tanks with a vacuum leak detection system are used the cinematic viscosity of the stored media shall not exceed 0.005 m2/s.

This standard is applicable for normal ambient temperature conditions (-20 degrees C to + 50 degrees C).

This standard is not applicable to the storage of dangerous liquids such as explosives, substances liable to spontaneous combustion, substances which in contact with water emit flammable gases, organic peroxides, infectious substances, radioactive material, hydrocyanic or hydrocyanic solvent liquids, metalcarbonyls, hydrofluoracid and bromide liquids.

This standard does not cover the installation of tanks which might be subject to local regulations involving pollution control.

 