Verification Method B1/VM4: Foundations
- Abbreviation
- B1/VM4 (Amd 17)
- Amendment
- 17
- Version
- First Edition, Amendment 17
- Valid to
- 31/10/2019
- Valid from
- 30/11/2018
This resource is no longer current. B1/VM4 (Amd 21) (First Edition, Amendment 21),
- Information provider
- Ministry of Business, Innovation and Employment,
- Information type
- Verification Method,
- Format
- PDF,
Description
Verification Method B1/VM4 provides a means of compliance with Building Code Clause B1 Structure.
This document covers the ultimate limit state design of foundations, including those of earth retaining structures. Methods are given for determining ultimate bearing and lateral sliding strengths.
Scope
This document does not describe a means of determining the value of the soil parameters used in the document (e.g. cI, fI and su). The derivation of these parameters, which must be based on the most adverse moisture and groundwater conditions likely to occur, is outside of the scope of this verification method.
Serviceability limit state deformations are not covered in this document. The determination of such deformations and their acceptability to the design in question needs to be considered but is outside the scope of this document.
This document assumes general ground or slope stability and provides methods only for ensuring against local failure of the foundation. Overall ground stability needs to be verified before this document can be applied; this is outside the scope of this verification method.
This document must not be used to design foundations on loose sands, saturated dense sands or on cohesive soils having a sensitivity greater than 4.
This document shall not be used for foundations subject to continuous vibration.
This resource is not cited by any other resources.
Verification Method B1/VM4: Foundations
This document is not CITED BY any other resources:
This resource cites:
Verification Method B1/VM4: Foundations
This document CITES:
B1/VM4 (Amd 17) cites AS/NZS 1170.0:2002 Structural Design Actions - General principles from 1/12/2008
B1/VM4 (Amd 17) cites AS/NZS 1170.1:2002 (R2016) Structural Design Actions - Permanent, imposed and other actions from 1/12/2008
B1/VM4 (Amd 17) cites AS/NZS 1170.2:2011 (R2016) Structural Design Actions - Wind Actions from 14/02/2014
B1/VM4 (Amd 17) cites AS/NZS 1170.3:2003 (R2016) Structural Design Actions - Snow and ice actions from 1/12/2008
B1/VM4 (Amd 17) cites NZS 3603:1993 Timber structures standard from 1/09/1993
B1/VM4 (Amd 17) cites NZS 3605:2001 Timber piles and poles for use in building - SPONSORED from 30/09/2010
B1/VM4 (Amd 17) cites NZS 3640:2003 Chemical preservation of round and sawn timber - SPONSORED from 30/09/2010
B1/VM4 (Amd 17) cites NZS 4402.4.2.3:1988 Methods of testing soils for civic engineering purposes - Soil compaction tests - Determination of the minimum and maximum dry densities and relative density of a cohesionless soil - Test 4.2.3 Relative density - SPONSORED from 1/12/2000
B1/VM4 (Amd 17) cites AS 2159-1995 Rules for the design and installation of piling (known as the SAA Piling Code) from 1/12/2000
B1/VM4 (Amd 17) cites ASTM D1143 - 81(1987)e1 Test method for piles under static axial compressive load from 1/12/2000
B1/VM4 (Amd 17) cites BS 8004:1986 Code of practice for foundations from 1/07/1992