BS 7777-3:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank
- Abbreviation
- BS 7777-3:1993
- Valid from
- 15/06/1993
- Information provider
- British Standards Institution,
- Author
- British Standards Institution
- Information type
- British Standard,
- Format
- PDF, HARD COPY,
Description
Information on the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank insulation, tank liners and tank coatings
This Standard gives recommendations that are applicable for single, double or full containment tanks at service temperatures down to -165 $0DC and single containment tanks down to -196 $0DC.
This resource is cited by:
BS 7777-3:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank
This document is CITED BY:
-
G14/VM1 (Amd 6) (Second Edition, Amendment 6)
BS 7777-3:1993 is cited by Verification Method G14/VM1: Industrial Liquid Waste from 21/06/2007
-
G14/VM1 (Amd 5) (Second Edition, Amendment 5)
BS 7777-3:1993 is cited by Verification Method G14/VM1: Industrial Liquid Waste from 21/06/2007
-
G14/VM1 (Second Edition, Amendment 4)
BS 7777-3:1993 is cited by Verification Method G14/VM1: Industrial Liquid Waste from 21/06/2007
-
G14/VM1 (Amd 3) (Second Edition, Amendment 3)
BS 7777-3:1993 is cited by Verification Method G14/VM1: Industrial Liquid Waste from 21/06/2007
-
BS 7777-1:1993
BS 7777-3:1993 is cited by BS 7777-1:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Guide to the general provisions applying for design, construction, installation and operation
-
BS 7777-2:1993
BS 7777-3:1993 is cited by BS 7777-2:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165
This resource cites:
BS 7777-3:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Recommendations for the design and construction of prestressed and reinforced concrete tanks and tank foundations, and for the design and installation of tank
This document CITES:
BS 7777-3:1993 cites BS 8004:1986 Code of practice for foundations
BS 7777-3:1993 cites BS 4447:1973 Specification for the performance of prestressing anchorages for post-tensioned construction
BS 7777-3:1993 cites BS 4449:1988 Specification for carbon steel bars for the reinforcement of concrete
BS 7777-3:1993 cites BS 4482:1985 Specification for cold reduced steel wire for the reinforcement of concrete
BS 7777-3:1993 cites BS 4483:1985 Specification for steel fabric for the reinforcement of concrete
BS 7777-3:1993 cites BS 4486:1980 Specification for hot rolled and hot rolled and processed high tensile alloy steel bars for the prestressing of concrete
BS 7777-3:1993 cites BS 5328-1:1991 Concrete - Part 1: Guide to specifying concrete
BS 7777-3:1993 cites BS 5328-2:1991 Concrete - Part 2: Methods for specifying concrete mixes
BS 7777-3:1993 cites BS 5328-3:1990 Concrete - Part 3: Specification for the procedures to be used in producing and transporting concrete
BS 7777-3:1993 cites BS 5328-4:1990 Concrete - Part 4: Specification for the procedures to be used in sampling, testing and assessing compliance of concrete
BS 7777-3:1993 cites BS 5896:1980 Specification for high tensile steel wire and strand for the prestressing of concrete
BS 7777-3:1993 cites BS 5930:1981 Code of practice for site investigations
BS 7777-3:1993 cites BS 7777-1:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Guide to the general provisions applying for design, construction, installation and operation
BS 7777-3:1993 cites BS 7777-2:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service. Specification for the design and construction of single, double and full containment metal tanks for the storage of liquefied gas at temperatures down to -165
BS 7777-3:1993 cites BS 7777-4:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service - Part 4: Specification for the design and construction of single containment tanks for the storage of liquid oxygen, liquid nitrogen and liquid argon
BS 7777-3:1993 cites BS 8007:1987 Code of practice for design of concrete structures for retaining aqueous liquids
BS 7777-3:1993 cites BS 8110-1:1985 Structural use of concrete. Code of practice for design and construction
BS 7777-3:1993 cites BS 8110-2:1985 Structural use of concrete. Code of practice for special circumstances
BS 7777-3:1993 cites BS EN 10045-1:1990 Charpy impact test on metallic materials. Test method (V- and U-notches)