AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements
- Abbreviation
- AS/NZS 3013:2005
- Valid from
- 21/08/2005
- Replaces
- AS/NZS 3013:1995,
- Information provider
- Standards New Zealand,
- Author
- Standards New Zealand, Standards Australia
- Information type
- New Zealand Standard,
- Format
- PDF, HARD COPY,
Description
This Standard sets out a classification scheme for wiring systems according to their resistance to the hazards of fire and mechanical damage.
Type tests to verify the level of protection provided by a wiring system are given. Intended for reference in other Standards which specify wiring systems with a degree of resistance to damage from fire or mechanical impact.
Scope
This Standard sets out a classification system for wiring system elements.
The classification is according to the wiring systems ability to
- (a) maintain circuit integrity under fire conditions for a specified period; and
- (b) maintain circuit integrity against mechanical damage of specified severity.
It specifies type tests to classify the performance of the various types of wiring system elements. If an assembled wiring system is tested to this Standard, the classification achieved cannot be assigned to any one of its individual elements.
The wiring system classification achieved shall only be applicable to the assembled wiring system as tested. This Standard does not address the screening function of screened cables after exposure to fire conditions.
This resource is cited by:
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements
This document is CITED BY:
-
AS 1530.4-2005
AS/NZS 3013:2005 is cited by AS 1530.4-2005 Methods for fire tests on building materials, components and structures. Part 4: Fire-resistance test of elements of construction
-
AS 1668.1:2015
AS/NZS 3013:2005 is cited by AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings
-
AS/NZS 3000:2007
AS/NZS 3013:2005 is cited by AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
-
AS/NZS 3000:2018
AS/NZS 3013:2005 is cited by AS/NZS 3000:2018 Electrical installations - Known as the Australian/New Zealand Wiring Rules
-
NZS 4510:2008
AS/NZS 3013:2005 is cited by NZS 4510:2008 Fire hydrant systems for buildings - SPONSORED
-
NZS 4512:2010
AS/NZS 3013:2005 is cited by NZS 4512:2010 Fire detection and alarm systems in buildings -SPONSORED
-
NZS 4512:2021
AS/NZS 3013:2005 is cited by NZS 4512:2021 Fire detection and alarm systems in buildings -SPONSORED