Verification Method B1/VM4: Foundations
- Abbreviation
- B1/VM4 (Amd 12)
- Amendment
- 12
- Version
- First edition, Amendment 12
- Valid to
- 31/05/2016
- Valid from
- 14/02/2014
This resource is no longer current. The current version is B1/VM4 (Amd 21) (First Edition, Amendment 21)
- Information provider
- Ministry of Business, Innovation and Employment
- Information type
- Verification Method
- Format
Description
Verification Method B1/VM4 provided a means of compliance with Building Code Clause B1 Structure.
This document covered the ultimate limit state design of foundations, including those of earth retaining structures.
Methods were given for determining ultimate bearing and lateral sliding strengths.
Scope
This document did not describe a means of determining the value of the soil parameters used in the document (e.g. cI, fI and su). The derivation of these parameters, which were based on the most adverse moisture and groundwater conditions likely to occur, was outside of the scope of this verification method.
Serviceability limit state deformations were not covered in this document. The determination of such deformations and their acceptability to the design in question needed to be considered but was outside the scope of this document.
This document assumed general ground or slope stability and provided methods only for ensuring against local failure of the foundation. Overall ground stability needed to be verified before this document could be applied; this was outside the scope of this verification method.
This document could not be used to design foundations on loose sands, saturated dense sands or on cohesive soils having a sensitivity greater than 4.
This document could not be used for foundations subject to continuous vibration.
This resource is not cited by any other resources.
Verification Method B1/VM4: Foundations
This document is not CITED BY any other resources:
This resource cites:
Verification Method B1/VM4: Foundations
This document CITES:
New Zealand Standards
-
AS/NZS 1170.0:2002
B1/VM4 (Amd 12) cites AS/NZS 1170.0:2002 Structural Design Actions - General principles from 1/12/2008
-
AS/NZS 1170.1:2002
B1/VM4 (Amd 12) cites AS/NZS 1170.1:2002 (R2016) Structural Design Actions - Permanent, imposed and other actions from 1/12/2008
-
AS/NZS 1170.2:2011
B1/VM4 (Amd 12) cites AS/NZS 1170.2:2011 (R2016) Structural Design Actions - Wind Actions from 14/02/2014
-
AS/NZS 1170.3:2003 (Reconfirmed in 2016)
B1/VM4 (Amd 12) cites AS/NZS 1170.3:2003 (R2016) Structural Design Actions - Snow and ice actions from 1/12/2008
-
NZS 3603:1993
B1/VM4 (Amd 12) cites NZS 3603:1993 Timber structures standard from 1/09/1993
-
NZS 3605:2001
B1/VM4 (Amd 12) cites NZS 3605:2001 Timber piles and poles for use in building - SPONSORED from 30/09/2010
-
NZS 3640:2003
B1/VM4 (Amd 12) cites NZS 3640:2003 Chemical preservation of round and sawn timber - SPONSORED from 30/09/2010
-
NZS 4402.4.2.3:1988
B1/VM4 (Amd 12) cites NZS 4402.4.2.3:1988 Methods of testing soils for civic engineering purposes - Soil compaction tests - Determination of the minimum and maximum dry densities and relative density of a cohesionless soil - Test 4.2.3 Relative density - SPONSORED from 1/12/2000
Australian Standards
-
AS 2159-1995
B1/VM4 (Amd 12) cites AS 2159-1995 Rules for the design and installation of piling (known as the SAA Piling Code) from 1/12/2000
Other
-
ASTM D1143 - 81(1987)e1
B1/VM4 (Amd 12) cites ASTM D1143 - 81(1987)e1 Test method for piles under static axial compressive load from 1/12/2000
-
BS 8004:1986
B1/VM4 (Amd 12) cites BS 8004:1986 Code of practice for foundations from 1/07/1992