ISO 13784-1:2014 Reaction to fire test for sandwich panel building systems — Part 1: Small room test

Abbreviation
ISO 13784-1:2014
Valid from
3/02/2014

Information provider
Standards New Zealand,
Author
International Organization for Standardization
Information type
ISO Standard,
Format
PDF, HARD COPY,


Description

ISO 13784-1:2014 specifies a method of test for determining the reaction to fire behaviour of sandwich panel building systems, and the resulting flame spread on or within the sandwich panel building construction, when exposed to heat from a simulated internal fire with flames impinging directly on the internal corner of the sandwich panel building construction.

The test method described is applicable to free-standing, self-supporting, and frame-supported sandwich panel systems. ISO 13784-1:2014 is not intended to apply to sandwich panel products which are glued, nailed, bonded, or similarly supported by an underlying wall or ceiling construction. For products used as internal linings, the ISO 9705 test method should be used.

Scope

ISO 13784-1:2014 provides for small room testing of sandwich panel building systems. For large-room testing of sandwich panel building systems, ISO 13784-2:2014 should be used.

This method is not intended to evaluate the fire resistance of a product, which should be tested by other means.

Previous versions:
ISO 13784-1:2002
For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

ISO 13784-1:2014 Reaction to fire test for sandwich panel building systems — Part 1: Small room test

This document is CITED BY:

ISO 13784-1:2014 Reaction to fire test for sandwich panel building systems — Part 1: Small room test

Description

ISO 13784-1:2014 specifies a method of test for determining the reaction to fire behaviour of sandwich panel building systems, and the resulting flame spread on or within the sandwich panel building construction, when exposed to heat from a simulated internal fire with flames impinging directly on the internal corner of the sandwich panel building construction.

The test method described is applicable to free-standing, self-supporting, and frame-supported sandwich panel systems. ISO 13784-1:2014 is not intended to apply to sandwich panel products which are glued, nailed, bonded, or similarly supported by an underlying wall or ceiling construction. For products used as internal linings, the ISO 9705 test method should be used.

View on Information Provider website
ISO 13784-1:2014 Reaction to fire test for sandwich panel building systems — Part 1: Small room test
Description

ISO 13784-1:2014 specifies a method of test for determining the reaction to fire behaviour of sandwich panel building systems, and the resulting flame spread on or within the sandwich panel building construction, when exposed to heat from a simulated internal fire with flames impinging directly on the internal corner of the sandwich panel building construction.

The test method described is applicable to free-standing, self-supporting, and frame-supported sandwich panel systems. ISO 13784-1:2014 is not intended to apply to sandwich panel products which are glued, nailed, bonded, or similarly supported by an underlying wall or ceiling construction. For products used as internal linings, the ISO 9705 test method should be used.

View on Information Provider website
This resource does not cite any other resources.

ISO 13784-1:2014 Reaction to fire test for sandwich panel building systems — Part 1: Small room test

This resource does not CITE any other resources.
Feedback