Verification Method E2/VM1: Cladding systems of buildings up to 10 m in height – including junctions with windows, doors and other penetrations
- Abbreviation
- E2/VM1 (Fourth edition)
- Version
- Fourth edition
- Valid from
- 28/07/2025
- Information provider
- Ministry of Business, Innovation and Employment,
- Information type
- Verification Method,
- Format
- PDF,
Description
E2 External Moisture Verification Method E2/VM1 Fourth Edition provides a compliance pathway for meeting the weathertightness performance requirements of Clause E2.3.2 of the New Zealand Building Code, specifically for cladding systems on buildings up to 10 metres in height.
The scope includes wall and roof cladding systems, including junctions with windows, doors, and penetrations, for buildings within the scope of NZS 3604 and designed for wind pressures up to 2500 Pa.
It is suitable for residential and similar buildings using drained and vented cavity systems.
The verification method outlines detailed test procedures including static, cyclic, and defect-based water penetration tests. The fourth edition includes updated formatting, consistent structure, and revised definitions.
Scope
This verification method sets out methods of compliance for external moisture provisions related to the penetration of water for cladding systems. It can be used to demonstrate compliance for:
- a) exterior wall cladding systems in Part 2. Wall cladding systems; and/or
- b) pitched roofing systems in Part 3. Roof cladding systems.
Additional limitations on the scope of this verification method are provided in Subsections 2.1.1 and 3.1.1.
Items outside the scope of this document
This verification method does not contain provisions for skillion roofs or commercial or industrial roofing.
This resource is not cited by any other resources.
Verification Method E2/VM1: Cladding systems of buildings up to 10 m in height – including junctions with windows, doors and other penetrations
This document is not CITED BY any other resources:
This resource cites:
Verification Method E2/VM1: Cladding systems of buildings up to 10 m in height – including junctions with windows, doors and other penetrations
This document CITES:
E2/VM1 (Fourth edition) cites AS/NZS 4284:2008 Testing of building facades from 1/08/2011
E2/VM1 (Fourth edition) cites NZS 3604:2011 Timber-framed buildings - SPONSORED from 1/08/2011
E2/VM1 (Fourth edition) cites AS 4046.9-2002 (R2015) Methods of testing roof tiles. Part 9: Determination of dynamic weather resistance from 1/07/2004