BS 8414-2:2015+A1:2017 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame

Abbreviation
BS 8414-2:2015+A1:2017
Valid from
23/06/2017

Information provider
Standards New Zealand,
Author
British Standards Institution
Information type
British Standard,
Format
PDF, HARD COPY,


Description

This British Standard provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when applied to the face of a bulding and exposed to an external fire under controlled conditions.

The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or from an external fire source.

Scope

This Standard does not cover the performance of glazed window openings or the detailing at such openings.

This Standard does not apply to curtain walling systems or systems that include glass panels.

NOTE: Performance Criteria and Classification mithodology of the external fire performance can be found in references, such as Report BR 135: Fire performance of external thermal insulation for walls of multi-storey buildings.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

BS 8414-2:2015+A1:2017 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame

This document is CITED BY:

BS 8414-2:2015+A1:2017 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame

Description

This British Standard provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when applied to the face of a bulding and exposed to an external fire under controlled conditions.

The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or from an external fire source.

View on Information Provider website
BS 8414-2:2015+A1:2017 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame
Description

This British Standard provides a test method for determining the fire performance characteristics of non-loadbearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when applied to the face of a bulding and exposed to an external fire under controlled conditions.

The fire exposure is representative of an external fire source or a fully-developed (post-flashover) fire in a room, venting through an opening such as a window aperture that exposes the cladding to the effects of external flames, or from an external fire source.

View on Information Provider website
This resource cites:

BS 8414-2:2015+A1:2017 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame

This document CITES:
Feedback