AS/NZS 3823.1.2:2012 Performance of electrical appliances - Airconditioners and heat pumps - Part 1.2: Ducted airconditioners and air-to-air heat pumps - Testing and rating for performance
- Abbreviation
- AS/NZS 3823.1.2:2012
- Valid from
- 1/06/2012
- Information provider
- Standards New Zealand,
- Author
- Standards New Zealand, Standards Australia
- Information type
- New Zealand Standard,
- Format
- PDF, HARD COPY,
Description
This Standard specifies the standard conditions for capacity and efficiency ratings of ducted, air-cooled air-conditioners and ducted air-to-air heat pumps.
This Standard is applicable to the test methods for determining the capacity and efficiency ratings. Residential, commercial, and industrial single-package and split-system air-conditioners and heat pumps are included. The equipment (taken to mean ducted air-conditioners and/or ducted heat pumps) shall be factory-made and electrically driven, and shall use mechanical compression. Adopted with national modifications from ISO 13253:2011.
Scope
This Standard is not applicable to the rating and testing of the following:
- a) water-source heat pumps or water-cooled air-conditioners;
- b) multi-split-system air-conditioners and air-to-air heat pumps (see ISO 15042 for testing of such equipment);
- c) mobile (windowless) units having a condenser exhaust duct;
- d) individual assemblies not constituting a complete refrigeration system;
- e) equipment using the absorption refrigeration cycle;
- f) non-ducted equipment (see ISO 5151 for testing of such equipment).
This Standard does not cover the determination of seasonal efficiencies that can be required in some countries because they provide a better indication of efficiency under actual operating conditions.
This resource is cited by:
AS/NZS 3823.1.2:2012 Performance of electrical appliances - Airconditioners and heat pumps - Part 1.2: Ducted airconditioners and air-to-air heat pumps - Testing and rating for performance
This document is CITED BY:
-
H1/VM3 (First edition) (First edition, unamended)
AS/NZS 3823.1.2:2012 is cited by Verification Method H1/VM3: Energy efficiency of HVAC systems in commercial buildings. from 29/11/2021
This resource cites:
AS/NZS 3823.1.2:2012 Performance of electrical appliances - Airconditioners and heat pumps - Part 1.2: Ducted airconditioners and air-to-air heat pumps - Testing and rating for performance
This document CITES:
AS/NZS 3823.1.2:2012 cites ISO 5151:2010 Non-ducted air conditioners and heat pumps — Testing and rating for performance
AS/NZS 3823.1.2:2012 cites ISO 817:2005 Refrigerants — Designation system
AS/NZS 3823.1.2:2012 cites ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)