AS 1735.16-1993 Lifts, escalators and moving walks Part 16: Lifts for persons with limited mobility - Restricted use - Automatically controlled
- Abbreviation
- AS 1735.16-1993
- Valid from
- 13/09/1993
- Information provider
- Intertek Inform,
- Information type
- Australian Standard,
- Format
- PDF, HARD COPY,
Description
Specifies requirements for automatically controlled, low-speed passenger lifts intended for infrequent use by persons with limited mobility.
Scope
This Standard specifies requirements for automatically controlled small-sized low-speed passenger lifts. The lifts are capable of being electrically isolated by a key-lockable control.
This Standard is complementary to AS 1735.1, but the requirements of this Standard take precedence over corresponding requirements of that Standard.
Notes:
- Guidance on periodic inspection and testing is given in Appendix A.
- This Standard is not intended to be applied to lifts that transport goods.
- This Standard is not complementary to either AS 1735.2 or AS 1735.3.
- Guidance on the selection of the preferred type of lift is given in Appendix B.
- This Standard applies to lifts that are primarily intended to be used by people with limited mobility who infrequently require a means of elevation to upper floors of their home, and in special cases, small community buildings that are not provided with lifts that comply with AS 1735.2 or 1735.3, subject to approval of the regulatory authorities.
- Lifts complying with this Standard -
- (a) have a low speed of not more than 0.25 m/s, or 0.3 m/s where car door is fitted.
- (b) have a small floor area of not more than 1.6 m2;
- (c) have a car travel of not more than 12 m; and
- (d) have a key-lockable control, so that the use of the lift can be restricted to persons holding a locking means.
This resource is cited by:
AS 1735.16-1993 Lifts, escalators and moving walks Part 16: Lifts for persons with limited mobility - Restricted use - Automatically controlled
This document is CITED BY:
-
AS 1668.2-2012
AS 1735.16-1993 is cited by AS 1668.2-2012 The use of ventilation and airconditioning in buildings - Part 2: Mechanical ventilation in buildings
-
AS 1668.2-2002
AS 1735.16-1993 is cited by AS 1668.2-2002 The use of ventilation and air-conditioning in buildings. Part 2 Ventilation design for indoor air contaminant control
-
AS/NZS 1170.1:2002
AS 1735.16-1993 is cited by AS/NZS 1170.1:2002 (R2016) Structural Design Actions - Permanent, imposed and other actions