This Standard sets out test procedures and criteria for the determination of fire-resistance of elements of building construction. Follows the basic principles and provisions contained in ISO 834:1975.
Scope
This Standard applies to heating conditions, test procedures, and criteria for the determination of fire-resistance of an element of building construction. In most cases, a single test, carried out in accordance with this Standard, establishes the fire-resistance for the element of construction concerned.
In addition to providing information on which the fire-resistance of an element of construction can be assessed, the test report includes information which may be of use to the designer. (Records of temperature at critical times may be used by a designer to assess the fire-resistance of a variant of the tested prototype flexural member where the procedure for such an assessment is defined in the appropriate design code.)
In certain cases, the test methods described herein provide information for the determination of
- (a) resistance to the incipient spread of fire through ceiling systems;
- (b) safe distances for the spacing of combustible materials from elements that provide a separating function;
- (c) radiant heat flux emitted from doorsets, shutter assemblies, damper assemblies and glazing; and
- (d) the free cross-sectional area of air ducts to provide functional operation while providing fire-resistance.
This resource is cited by:
AS 1530.4-1997 Methods for fire tests on building materials components and structures - Fire-resistance test of elements of building construction
This document is CITED BY:
-
AS/NZS 1668.1:1998
AS 1530.4-1997 is cited by AS/NZS 1668.1:1998 The use of ventilation and air conditioning in buildings - Fire and smoke control in multi-compartment buildings
-
NZS 3101.1:2006 (inc A1, A2)
AS 1530.4-1997 is cited by NZS 3101.1:2006 (inc A1, A2) Concrete structures standard. - Part 1: The design of concrete structures. - SPONSORED.
-
NZS 3101.2:2006 (inc A1, A2)
AS 1530.4-1997 is cited by NZS 3101.2:2006 (inc A1, A2) Concrete structures standard. - Part 2: Commentary on the design of concrete structures. - SPONSORED.
-
NZS 3101.2:2006 (inc A1, A2, A3)
AS 1530.4-1997 is cited by NZS 3101.2:2006 (inc A1, A2, A3) Concrete structures standard. - Part 2: Commentary on the design of concrete structures. - SPONSORED.
-
NZS 3404 Parts 1 and 2:1997
AS 1530.4-1997 is cited by NZS 3404 Parts 1 and 2:1997 Steel structures standard - SPONSORED
-
NZS 4230:2004
AS 1530.4-1997 is cited by NZS 4230:2004 Design of reinforced concrete masonry structures - SPONSORED
-
NZS 4515:2009
AS 1530.4-1997 is cited by NZS 4515:2009 Fire sprinkler systems for life safety in sleeping occupancies (up to 2000 square metres) - SPONSORED