LPCB LPS 1208:2014 LPCB fire resistance requirements for elements of construction used to provide compartmentation

Abbreviation
LPCB LPS 1208:2014
Version
Issue 2.2
Valid from
1/01/2014

Information provider
RedBookLive,
Author
BRE Global Ltd
Information type
Building specification,
Format
PDF,


Description

This standard defines the methods of tests and performance requirements in order to satisfy the fire resistance requirements for compartmentation given in the LPC Design Guide for the Fire Protection of Buildings.

The standard is applicable to the following elements of construction:

  • Loadbearing compartment walls
  • Non-loadbearing compartment walls and partitions
  • External walls
  • Curtain walls
  • Cavity barriers
  • Roofs where fire resistance is required (loadbearing and non-loadbearing)
  • Loadbearing compartment floors
  • Insulated panels used for enclosing production and storage areas in food factories

This standard is applicable to any type of construction system used for the above applications.

Scope

Products certified to this standard should also meet the relevant requirements of building regulations in relation to fire resistance.

It does not cover other performance requirements that may be needed to satisfy regulatory documents.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website Download this resource (PDF, 252KB)
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

LPCB LPS 1208:2014 LPCB fire resistance requirements for elements of construction used to provide compartmentation

This document is CITED BY:

LPCB LPS 1208:2014 LPCB fire resistance requirements for elements of construction used to provide compartmentation

Description

This standard defines the methods of tests and performance requirements in order to satisfy the fire resistance requirements for compartmentation given in the LPC Design Guide for the Fire Protection of Buildings.

The standard is applicable to the following elements of construction:

  • Loadbearing compartment walls
  • Non-loadbearing compartment walls and partitions
  • External walls
  • Curtain walls
  • Cavity barriers
  • Roofs where fire resistance is required (loadbearing and non-loadbearing)
  • Loadbearing compartment floors
  • Insulated panels used for enclosing production and storage areas in food factories

This standard is applicable to any type of construction system used for the above applications.

View on Information Provider website Download this resource (PDF, 252KB)
LPCB LPS 1208:2014 LPCB fire resistance requirements for elements of construction used to provide compartmentation
Description

This standard defines the methods of tests and performance requirements in order to satisfy the fire resistance requirements for compartmentation given in the LPC Design Guide for the Fire Protection of Buildings.

The standard is applicable to the following elements of construction:

  • Loadbearing compartment walls
  • Non-loadbearing compartment walls and partitions
  • External walls
  • Curtain walls
  • Cavity barriers
  • Roofs where fire resistance is required (loadbearing and non-loadbearing)
  • Loadbearing compartment floors
  • Insulated panels used for enclosing production and storage areas in food factories

This standard is applicable to any type of construction system used for the above applications.

View on Information Provider website Download this resource (PDF, 252KB)
This resource does not cite any other resources.

LPCB LPS 1208:2014 LPCB fire resistance requirements for elements of construction used to provide compartmentation

This resource does not CITE any other resources.
Feedback