IEC 61249-2-26:2005 Materials for printed boards and other interconnecting structures - Part 2-26: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminated sheets of defined flammability (vertical

Abbreviation
IEC 61249-2-26:2005
Valid from
11/01/2005

Information provider
International Electrotechnical Commission,
Author
International Electrotechnical Commission
Information type
IEC Standard,
Format
PDF, HARD COPY,


Description

This part of IEC 61249 gives requirements for properties of non-halogenated epoxide non-woven/woven reinforced E-glass laminated sheets of defined flammability (vertical burning test), copper-clad in thicknesses of 0,80 mm up to 1,60 mm. The flammability rating is achieved through the use of non-halogenated inorganic and/or organic compounds acting as fire retardants. These fire retardants are contained as part of polymeric structure or in addition to it. The glass transition temperature is defined to be 95 °C minimum.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

IEC 61249-2-26:2005 Materials for printed boards and other interconnecting structures - Part 2-26: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminated sheets of defined flammability (vertical

This document is CITED BY:

IEC 61249-2-26:2005 Materials for printed boards and other interconnecting structures - Part 2-26: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminated sheets of defined flammability (vertical

Description

This part of IEC 61249 gives requirements for properties of non-halogenated epoxide non-woven/woven reinforced E-glass laminated sheets of defined flammability (vertical burning test), copper-clad in thicknesses of 0,80 mm up to 1,60 mm. The flammability rating is achieved through the use of non-halogenated inorganic and/or organic compounds acting as fire retardants. These fire retardants are contained as part of polymeric structure or in addition to it. The glass transition temperature is defined to be 95 °C minimum.

View on Information Provider website
IEC 61249-2-26:2005 Materials for printed boards and other interconnecting structures - Part 2-26: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminated sheets of defined flammability (vertical
Description

This part of IEC 61249 gives requirements for properties of non-halogenated epoxide non-woven/woven reinforced E-glass laminated sheets of defined flammability (vertical burning test), copper-clad in thicknesses of 0,80 mm up to 1,60 mm. The flammability rating is achieved through the use of non-halogenated inorganic and/or organic compounds acting as fire retardants. These fire retardants are contained as part of polymeric structure or in addition to it. The glass transition temperature is defined to be 95 °C minimum.

View on Information Provider website
This resource does not cite any other resources.

IEC 61249-2-26:2005 Materials for printed boards and other interconnecting structures - Part 2-26: Reinforced base materials clad and unclad - Non-halogenated epoxide non-woven/woven E-glass reinforced laminated sheets of defined flammability (vertical

This resource does not CITE any other resources.
Feedback