Acceptable Solution G11/AS1: Gas as an Energy Source

This resource is no longer current. The current version is G11/AS1 (Amd 6) (First Edition, Amendment 6)

Abbreviation
G11/AS1 (Amd 5)
Amendment
5
Version
First Edition, Amendment 5
Valid to
30/05/2017
Valid from
14/02/2014

Information provider
Ministry of Business, Innovation and Employment
Information type
Acceptable Solution
Format
PDF


Description

Acceptable Solution G11/AS1 provides a means of compliance with Building Code Clause G11 Gas as an Energy Source. Clause G11 requires the safe installation of gas-fuelled appliances.

In buildings where gas is used as an energy source, the supply system shall be safe and adequate for its intended use. Supply systems must maintain safe pressure, ventilation and flues.

They must have automatic cut-off devices, allow for maintenance, and be installed to avoid contamination and adverse effects.

Meters and service risers must meet requirements of network utility operators.

Scope

This Acceptable Solution relates essentially to gas appliances. It should be read in conjunction with G10/AS1, which deals with piping reticulation

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website Download this resource (PDF, 1.0MB)
For assistance with locating previous versions, please contact the information provider.
This resource is not cited by any other resources.

Acceptable Solution G11/AS1: Gas as an Energy Source

This document is not CITED BY any other resources:

Acceptable Solution G11/AS1: Gas as an Energy Source

Description

Acceptable Solution G11/AS1 provides a means of compliance with Building Code Clause G11 Gas as an Energy Source. Clause G11 requires the safe installation of gas-fuelled appliances.

In buildings where gas is used as an energy source, the supply system shall be safe and adequate for its intended use. Supply systems must maintain safe pressure, ventilation and flues.

They must have automatic cut-off devices, allow for maintenance, and be installed to avoid contamination and adverse effects.

Meters and service risers must meet requirements of network utility operators.

View on Information Provider website Download this resource (PDF, 1.0MB)
Acceptable Solution G11/AS1: Gas as an Energy Source

This resource is no longer current. The current version is G11/AS1 (Amd 6) (First Edition, Amendment 6)

Description

Acceptable Solution G11/AS1 provides a means of compliance with Building Code Clause G11 Gas as an Energy Source. Clause G11 requires the safe installation of gas-fuelled appliances.

In buildings where gas is used as an energy source, the supply system shall be safe and adequate for its intended use. Supply systems must maintain safe pressure, ventilation and flues.

They must have automatic cut-off devices, allow for maintenance, and be installed to avoid contamination and adverse effects.

Meters and service risers must meet requirements of network utility operators.

View on Information Provider website Download this resource (PDF, 1.0MB)