Performance of mid-rise cladding systems, EM7 (June 2020)
- Abbreviation
- EM7 (June 2020)
- Version
- Version 3
- Valid from
- 1/06/2020
- Information provider
- BRANZ Limited,
- Information type
- Evaluation method,
- Format
- PDF,
Description
This avaluation method (EM7) represents a series of tests from AS/NZS 4284:2008 Testing of building facades, with specific nominated values for the performance levels.
EM7 provides a means of assessing the weathertightness-oriented performance of generic domestic-oriented external wall cladding systems for use on buildings between 10m and 25m in height and expects that a drained and ventilated cavity is used as part of the cladding design.
The aim is to provide a test with a consistent set of parameters for use in the design of claddings for mid-rise building.
Scope
The scope of EM7 is restricted to buildings that:
- have a height measured from the lowest ground level adjacent to the building to the highest point of the roof (except for chimneys, aerials and the like) of 25m or less
- have cladding systems exposed to a specific peak positive SLS air pressure of up to 2.25kPa (ULS 3.2kPa)
- have claddings that include a drained and ventilated cavity of 20mm minimum depth with an inter-storey horizontal drainage joint every 2 floors, or 7.0m, and minimum ventilation openings of 1000mm2/m
- include window and door units that are manufactured to comply with the relevant pressures and inter-storey deflections
- have interp-storey deflections design for up to +15mm of horizontal in-plane movement during seismic SLS events assuming a 3m inter-storey height (height/200)
- have cladding supported on lightweight framing (expected to be timber or light steel framing) with studs at centres no greater than 600mm that is structurally connected to the floor at each level of the building - this evaluation method is not intended to be used with infill framing that is isolated from structural movement of the building
- have a rigid building underlay affixed to the framing
This resource is cited by:
Performance of mid-rise cladding systems, EM7 (June 2020)
This document is CITED BY:
-
E2/VM2 (First Edition) (First Edition)
EM7 (June 2020) is cited by Verification Method E2/VM2: Cladding systems for buildings up to 25 m in height – including junctions with windows, door and other penetrations. from 27/06/2019
-
E2/VM2 (Second Edition) (Second edition)
EM7 (June 2020) is cited by Verification Method E2/VM2: Cladding systems for buildings up to 25 m in height – including junctions with windows, door and other penetrations. from 27/06/2019
This resource cites:
Performance of mid-rise cladding systems, EM7 (June 2020)
This document CITES:
EM7 (June 2020) cites AS/NZS 1170.2:2011 (R2016) Structural Design Actions - Wind Actions
EM7 (June 2020) cites AS/NZS 4284:2008 Testing of building facades
EM7 (June 2020) cites AAMA 508-14 Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems.
EM7 (June 2020) cites ASTM E1677-11 Standard Specification for Air Barrier (AB) Material or System for Low-Rise Framed Building Walls