Velo Facades® rainscreen cladding system
- Abbreviation
- CMNZ70226 version: 0
- Version
- 0
- Valid from
- 30/09/2026
- Information provider
- Ministry of Business, Innovation and Employment,
- Author
- Bureau Veritas Australia Pty Ltd
- Information type
- Product Certificate (CodeMark),
- Format
- PDF,
Description
Certificate holder: Woodform Architectural Pty Ltd.
The Velo Facades® system is an exterior rainscreen cladding system.
Velo Facades® rainscreen cladding system consists of a click-on aluminium cladding, an optional continuous cavity insulation and a standard cavity with either a rigid air barrier or flexible weather-resistant membrane.
- Thermal Cavity System incorporates thermal insulation external to a rigid air barrier.
- Standard Cavity System does not incorporate thermal insulation (but insulation may be incorporated within the framed structure to which it is attached - outside the scope of this certification).
Velo Facades® rainscreen cladding system features an extruded aluminium mounting track with a proprietary clip mechanism and extruded aluminium panels, available in three finishes:
- Polyolefin Film Wrapped
- Powder Coated
- Anodised.
Scope
1. The Velo Facades® rainscreen cladding system is certified for use on buildings:
- a. designed in accordance with:
- i. NZS 3604:2011 Timber-framed buildings, as modified by B1/AS1 or of at least equivalent stiffness to the framing provisions of NZS 3604:2011 or;
- ii. NASH, Standard Part 2, or of at least equivalent stiffness to the framing provisions of NZS 3604:2011, and;
- iii. within the scope of E2/AS1, sub section 1.1.1, and;
- iv. situated in Wind Zones (as defined in NZS 3604:2011) up to and including Extra High, or;
- v. designed in accordance with B1/VM1 up to a maximum design differential serviceability limit state (SLS) wind pressure of 2.0 kPa for Standard Cavity and 3.0 kPa for Thermal Cavity, and maximum ultimate limit state differential wind pressure (ULS) applicable to the cladding and span (see 2 (a), and;
- b. up to 10 m in height, and;
- c. with a risk score of 0-20 calculated in accordance with E2/AS1, Table 3.1.3.1, and;
- d. situated:
- i. in all exposure zones (excluding microclimates) as defined in NZS 3604:2011, Paragraph 4.2.4, except that fasteners to framing in exposure zones D and E shall be stainless steel, and;
- ii. anywhere with respect to a relevant boundary;
2. The Velo Facades® rainscreen cladding system shall:
- a. be designed in accordance with the span tables in Product Technical Datasheet High-Performance Rainscreen Façade System Rev 2. 6 August 2025 and;
- b. be installed in accordance with the Velo Facades® Installation Guide New Zealand, Version 1.0, June 2026 and;
- c. be fixed using galvanised or stainless-steel fixings as specified, and;
- d. only incorporate aluminium framed window and door joinery complying with Section 4.4 of the Building Product Specifications. which shall be installed with vertical jambs and horizontal heads and sills.
3. The fire engineering design for multilevel buildings within the scope of C/AS2 subsection 1.1.1 must include specific detailing at each floor level to meet the requirements for cavity barriers as specified in C/AS2, Paragraph 5.5.3.1.