Masons UNI® and UNI® PLUS Flexible Air Barriers
- Abbreviation
- CMNZ70116 version 2
- Version
- 2
- Valid from
- 22/07/2024
- Information provider
- Ministry of Business, Innovation and Employment,
- Author
- Bureau Veritas Australia Pty Ltd
- Information type
- Product Certificate (CodeMark),
- Format
- PDF,
Description
Masons UNI® and UNI® PLUS Flexible Air Barriers are wall underlays and flexible air barriers and are suitable for use as temporary weather protection to allow interior works to continue inside the building without the exterior wall cladding fully in place.
UNI® PLUS Flexible Air Barrier is fire retardant and suitable for use where exposed to view in an occupied space.
Masons UNI® and UNI® PLUS Flexible Air Barriers are tri-laminate synthetic sheets 2.74 metres wide consisting of two outer non-woven layers and a middle synthetic membrane which is dark grey.
- UNI® Flexible Air Barrier has a blue front face marked "UNI® Flexible Air Barrier" and a black rear face.
- UNI® PLUS Flexible Air Barrier has a blue front face marked "UNI® PLUS Flexible Air Barrier" and a white rear face.
- UNI® Flexible Air Barrier is also available as 600 mm wide sheet with a self-adhesive strip, marketed as UNI® Soffit.
Scope
1. Masons UNI® and UNI® PLUS Flexible Air Barriers are certified for use as a wall underlay and air barrier on buildings:
- a. within the scope limitations of:
- i. NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and floor plan area for timber-framed construction; or
- ii. NZBC Acceptable Solution E2/AS4 with regards to building height and floor plan area for light-steel framed construction, and
- b. situated in wind zones (as defined in NZS 3604:2011) up to and including ‘Extra High’, provided stud and fixing centres are no greater than specified in the Masons UNI® Flexible Air Barrier Design and Installation Manual V1.0, October 2021 - CM, or the Masons UNI® PLUS Flexible Air Barrier Design and Installation Manual V2.0, March 2022 - CM respectively, and
- c. with absorbent or non-absorbent wall claddings directly fixed to the frame; or installed over an 18 mm minimum drained cavity; or with masonry veneer, in accordance with NZBC Acceptable Solution E2/AS1 for timber framed buildings or NZBC Acceptable Solution E2/AS4 for steel framed buildings, and
- d. Masons UNI® Flexible Air Barrier must not be used where the underlay is exposed to view in an occupied space.
- e. Masons UNI® PLUS Flexible Air Barrier may be used when exposed to view in an occupied space.
2. Masons UNI® and UNI® PLUS Flexible Air Barriers shall be:
- a. installed in accordance with the Masons UNI® Flexible Air Barrier Design and Installation Manual V1.0, October 2021 - CM, or the Masons UNI® PLUS Flexible Air Barrier Design and Installation Manual V2.0, March 2022 - CM respectively, and
- b. separated from fireplaces, heating appliances, flues and chimneys in accordance with the requirements of NZBC Acceptable Solutions C/AS1 and C/AS2, Paragraph 7.5.9 for the protection of combustible materials, and
- c. protected from sunlight within 90 days
3. Contribution to compliance with Building Code clause H1.3.1(b) is conditional on:
- a. the element incorporating Masons UNI® and UNI® PLUS Flexible Air Barrier being part of the thermal envelope of the building, and
- b. horizontal and vertical laps being securely taped.