Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System

Abbreviation
CMNZ30106 version D
Version
D
Valid from
3/02/2025

Information provider
Ministry of Business, Innovation and Employment,
Author
Global-Mark Pty Ltd
Information type
Product Certificate (CodeMark),
Format
PDF,

Description

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System comprise timber weatherboards, fascia boards, moulding profiles and castellated cavity battens manufactured from radiata pine that has been thermally modified or chemically treated. Profiles may be finger jointed or solid.

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System is designed to be used as part of an external cladding system.

Scope

1. The Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System is certified as an external wall cladding for buildings within the following scope:

  • a. with timber or lightweight steel framing that complies with the NZ Building Code or for existing buildings that has the equivalent stiffness to the framing provisions of NZS3604:2011, and
  • b. in wind zones up to and including extra high as defined in NZS3604:2011, or for Specifically Engineer Designed buildings with a maximum design Ultimate Limit State (ULS) wind pressure of 2.5kPa, and
  • c. in exposure Zones B, C and D as defined in NZS3604:2011. Microclimatic Conditions (refer NZS3604:2011 paragraph 4.2.4) are outside the scope of this certificate for both timber framed and steel framed buildings, and
  • d. up to 10 m in building height, and
  • e. further than 1m from a relevant and notional boundary, unless compliance may be established (outside the scope of this certificate) through reliance on NZBC Acceptable Solution C/AS1, 2nd edition (2/11/ 2023) or NZBC Acceptable Solution C/AS2 amendment 3 (2/11/ 2023).

2. The Pineclad & Pineclad TMT Vertical Weatherboard External Cladding shall be:

  • a. Used in conjunction with a flexible building wrap or rigid air barrier depending on location wind zone and as a minimum, in accordance with:
    • i. NZBC Acceptable Solution E2/AS1, Third Edition including amendment 10 (5/11/2020) Table 23 for timber framed buildings, or
    • ii. NASH building Envelop Solution (2019) Table 23 for steel framed buildings, or
    • iii. a current Codemark certificate or BRANZ appraisal demonstrating suitability for the use conditions, and
  • b. Directly fixed or fixed over a ventilated cavity in accordance with Table 3, E2/AS1 or E2/AS4. For applications not referenced in the applicable acceptable solution, the cladding will be installed over a ventilated cavity, and
  • c. used on buildings with a risk score not greater than 20, when evaluated against:
    • i. NZBC Acceptable Solution E2/AS1, Third Edition including amendment 10 (5/11/2020) risk matrix for timber framed building or
    • ii. NASH building Envelope Solution (2019) risk matrix as referenced by E2/AS4 for steel framed buildings, and
  • d. used with aluminium window and door joinery that meets the requirements of NZS 4211:2008 including amendment 1 or has a current Product Certificate or with traditional timber joinery as set out in BRANZ bulletin BU481, and
  • e. where Pineclad is finished with a paint coating, the LRV of the top coating paint must not be less than 45% (excludes Pineclad TMT).

3. The Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System must be specified, installed and maintained in accordance with the following documentation:

  • a. Pineclad and Pineclad TMT Vertical Weatherboard Cladding Systems – Design Guide – V2.1 – May 2024, and
  • b. Pineclad and Pineclad TMT Vertical Weatherboard Cladding Systems – Installation Guide – V2.1 – May 2024, and
  • c. Pineclad and Pineclad TMT Board & Batten Weatherboard Cladding System – Specification Guide – V2.1 – May 2024, and
  • d. Pineclad and Pineclad TMT Shiplap Weatherboard Cladding System – Specification Guide – V2.1 – May 2024, and
  • e. Pineclad and Pineclad TMT Weatherboard Cladding Systems – Care & Maintenance Guide – V2.1 – May 2024.
  • f. Pineclad and Pineclad TMT Board & Batten Direct Fixed Details – V2.1
  • g. Pineclad and Pineclad TMT Board & Batten Cavity Fixed Details – V2.1
  • h. Pineclad and Pineclad TMT Shiplap Direct Fixed Details – V2.1
  • i. Pineclad and Pineclad TMT Shiplap Cavity Fixed Details – V2.1

4. System specification and installation must be carried out by or supervised by a Licensed Building Practitioner who has:

  • a. The relevant license class, and
  • b. access to current Hume Pine technical documentation.

5. Certification of compliance with E2.3.5 and E2.3.6 is limited to the cavity formed between the back of the weatherboards and the underlay.

6. A completed specification guide for the profile selected shall be included with the building consent application.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is not cited by any other resources.

Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System

This document is not CITED BY any other resources:

Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System

Description

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System comprise timber weatherboards, fascia boards, moulding profiles and castellated cavity battens manufactured from radiata pine that has been thermally modified or chemically treated. Profiles may be finger jointed or solid.

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System is designed to be used as part of an external cladding system.

View on Information Provider website
Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System
Description

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System comprise timber weatherboards, fascia boards, moulding profiles and castellated cavity battens manufactured from radiata pine that has been thermally modified or chemically treated. Profiles may be finger jointed or solid.

The Pineclad and Pineclad TMT Vertical Weatherboard External Cladding System is designed to be used as part of an external cladding system.

View on Information Provider website
This resource does not cite any other resources.

Pineclad & Pineclad TMT Vertical Weatherboard External Cladding System

This resource does not CITE any other resources.
Feedback