Knauf Insulation

Abbreviation
CMNZ30095 version C
Version
C
Valid from
15/01/2025

Information provider
Ministry of Business, Innovation and Employment,
Author
Global-Mark Pty Ltd
Information type
Product Certificate (CodeMark),
Format
PDF,

Description

Knauf Insulation and Earthwool® glasswool is a mineral fibre type bulk insulation with DriTherm® technology that complies with AS/NZS 4859.1:2018 and is supplied as batts or rolls with thickness between 50 mm and 275 mm, and nominal density between 8 kg/m3 and 32 kg/m3 with binder content no greater than 8%.

Non-combustible bulk thermal and acoustic insulation for residential and commercial construction within the following scope and NZS 4246:2016:

  • Walls when installed in the cavities between framing members.
  • Floors when installed in the cavities between flooring members.
  • Roofs when installed over and between roof framing.
  • Ceilings when installed in the cavities between the ceiling members.

Scope

1. Specification and incorporation of Earthwool® glasswool insulation products into the building design shall be carried out by a designer, architect, engineer, or building professional in accordance with NZS 4214:2006 Methods of Determining the Total Thermal Resistance of Parts of Buildings and NZS 4218:2009 Thermal Insulation – Housing and Small Buildings when incorporating Knauf Insulation products to achieve the required building performance.

2. Specification of Knauf Insulation products shall be in accordance with the following:

 Knauf Insulation Product Datasheets – www.knaufinsulation.co.nz

3. Installation shall be carried out by a competent bulk insulation installer and installed in accordance with NZS 4218:2009 Thermal insulation - Housing and small buildings, or NZS 4246:2016 Energy efficiency – Installing bulk thermal insulation in residential buildings. To meet the stated thermal performance rating of the insulation the relevant installation instructions should be followed, as stated at:

Knauf Insulation installation instructions – www.knaufinsulation.co.nz

4. Installation shall be carried out only after the building is waterproof, and after the materials within the building have dried to a sufficient degree that moisture is not transported into the insulation material.

5. In residential construction, installation shall also be carried out in accordance with NZS 4246:2016 Energy efficiency – Installing bulk thermal insulation in residential buildings

6. Refer to Table 1 for a schedule of Knauf Insulation products covered by this certificate.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is not cited by any other resources.

Knauf Insulation

This document is not CITED BY any other resources:

Knauf Insulation

Description

Knauf Insulation and Earthwool® glasswool is a mineral fibre type bulk insulation with DriTherm® technology that complies with AS/NZS 4859.1:2018 and is supplied as batts or rolls with thickness between 50 mm and 275 mm, and nominal density between 8 kg/m3 and 32 kg/m3 with binder content no greater than 8%.

Non-combustible bulk thermal and acoustic insulation for residential and commercial construction within the following scope and NZS 4246:2016:

  • Walls when installed in the cavities between framing members.
  • Floors when installed in the cavities between flooring members.
  • Roofs when installed over and between roof framing.
  • Ceilings when installed in the cavities between the ceiling members.

View on Information Provider website
Knauf Insulation
Description

Knauf Insulation and Earthwool® glasswool is a mineral fibre type bulk insulation with DriTherm® technology that complies with AS/NZS 4859.1:2018 and is supplied as batts or rolls with thickness between 50 mm and 275 mm, and nominal density between 8 kg/m3 and 32 kg/m3 with binder content no greater than 8%.

Non-combustible bulk thermal and acoustic insulation for residential and commercial construction within the following scope and NZS 4246:2016:

  • Walls when installed in the cavities between framing members.
  • Floors when installed in the cavities between flooring members.
  • Roofs when installed over and between roof framing.
  • Ceilings when installed in the cavities between the ceiling members.
View on Information Provider website
This resource does not cite any other resources.

Knauf Insulation

This resource does not CITE any other resources.
Feedback