Description
Viking GM Torch-On Membrane Systems are a range of torch-applied reinforced modified-bitumen membranes for use as fully bonded double-layer torch-on waterproofing membranes on nominally flat and pitched roofs.
Viking GM Torch-On Membrane Systems are roof waterproofing membrane systems.
There are four Viking GM Torch-On Membrane Systems:
- Phoenix Super APAO
- Lybra SBS,
- Gemini APP and
- Halley-P (No-Flame).
Scope
1. Viking GM Torch-On Membrane Systems are certified for use as a roof waterproofing membrane:
- a) on buildings:
- i. within the scope limitations of NZS 3604:2011 and NZBC Acceptable Solution E2/AS1, Third Edition including amendment 10 (5/11/2020), Paragraph1.1; or,
- ii. within the scope limitations of NZBC Acceptable Solution E2/AS1, Third Edition including amendment 10 (5/11/2020), Paragraph 1.1 with regards to building height and floor plan area, when subject to specific structural design; and,
- iii. situated in NZS 3604:2011 Wind Zones, up to, and including Extra High, and
- iv. with substrates of Plywood, concrete or Strandsarking® (roof only), and
- v. with a minimum fall in accordance with the finish fall requirement of the Code of Practice for Reinforced Modified Bitumen Membraned (RMBM) Systems for Roofs and Decks, 4th Edition, March 2021.
- b) on specifically designed or existing buildings:
- i. subject to specific structural and weathertightness design situated in wind pressures up to a maximum design differential ultimate limit state (ULS) specified in #2 below; and
- ii. with substrates of Plywood, concrete or Strandsarking® (roof only), and
- iii. with a minimum fall in accordance with the finish fall requirement of the Code of Practice for Reinforced Modified Bitumen Membraned (RMBM) Systems for Roofs and Decks, 4th Edition, March 2021.
- c) where the membrane is on a trafficable area of a roof it must be continually protected from physical damage by pedestal protection system or other approved means.
2. Subject to the structural limitations of the substrate, Viking GM Torch-On Membrane Systems are certified for use up to a maximum design differential Ultimate Limit State wind pressure of 6 kPa.
3. Viking GM Torch-On Membrane Systems shall be:
- a) designed and installed in accordance with the requirements of the BRANZ Appraisal 948 (2022) – Viking GM Torch On Membranes (Amended 15 December 2022) and the Technical Literature “Viking_Roofspec_Torch-On Details_201123”, 23 November 2020, and
- b) Installed by a Viking Roofspec trained and licensed installer.
4. For existing buildings, the suitability of the substrate shall be confirmed by a professional qualified to design buildings within the scope specified in Condition #1.
5. Product specification and incorporation of the Viking GM Torch-On Membrane Systems into the building design shall be carried out by a competent building professional, qualified to design buildings within the scope specified in Condition #1.
6. This certification does not include:
- a) details not covered by the Technical Literature, which shall be subject to specific weathertightness design, and
- b) the design and construction of the substrate including movement and control joints, and
- c) applications where ancillary components other than those provided by Viking Roofspec listed in the Technical Literature are substituted with alternative products, and
- d) integral roof gardens, steps within the roof surface and direct downpipe discharge to the roof level.