JSC BevelClad Cladding System

Abbreviation
CMNZ30082 version: J
Version
J
Valid from
1/05/2026

Information provider
Ministry of Business, Innovation and Employment,
Author
Global-Mark Pty Ltd
Information type
Product Certificate (CodeMark),
Format
PDF,

Description

Certificate holder: J.Scott and Company Limited, t/a JSC.

The JSC BevelClad Cladding System is an external wall cladding installed over a 20 mm or 45 mm ventilated cavity.

The BevelClad Cladding System (the System) comprises of horizontally fixed weatherboards installed over H3.2 treated timber cavity battens to form a either a 20 mm cavity or a 45 mm cavity, fascia boards and moulding profiles.

JSC BevelClad Cladding System weatherboards are manufactured from the following materials:

  • Western Red Cedar (Thuja Plicata)
  • Alaskan Yellow Cedar (Cupressus nootkatensis)
  • Radiata Pine – H3.2 (MicroPro® treated)
  • Nordic Pine - H3.2 (MicroPro® treated)
  • Iroko (Milicia excelsa)
  • TMT Amba
  • TMT Taiga RW
  • TMT Taiga WW
  • TMT Taxon
  • TMT Tuscan
  • TMT ThermoPine
  • TMT ThermoPine H3.2 MicroPro® treated.

Scope

1. The system is certified for timber-framed buildings:

  • a. with walls designed in accordance with NZS3604:2011 Timber-framed buildings, as modified by Acceptable Solution B1/AS1 and within the scope of Acceptable Solution E2/AS1, Sub-section 1.1.1, or of at least equivalent stiffness to the framing provisions of NZS3604:2011, and situated in Wind Zones (as defined in NZS 3604:2011) up to and including Extra High; or
  • b. subject to specific engineering design in accordance with Verification Method B1/VM1 up to a maximum design differential ultimate limit state (ULS) wind pressure of 2.5 kPa, and
  • c. up to 10 m in height, and 
  • d. with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/AS1 Tables 3.1.2.1 and 3.1.3.1, and
  • e. situated:
    • i. in all exposure zones (excluding microclimates) as defined in NZS3604:2011, Paragraph 4.2.4, and
    • ii. more than 1m from a relevant boundary.

2. The System shall be designed, used, installed and maintained in accordance the following sets of documents collectively referenced as the Applicable Technical Specification:

  • a. Design Guide - JSC BevelClad – Horizontal Bevel Back Weatherboard Cladding, V1.0, February 2026
  • b. Installation Guide - JSC BevelClad - Bevelback Weatherboard Cladding - Guide v3.7, Dated February 2026
  • c. JSC BevelClad - Installation Checklist v1.4, February 2026
  • d. Site Drawings - JSC BevelClad - Bevel Back Weatherboards - Flexible Underlay 20mm Cavity Fix, v2.6, 11/02/2026
  • e. Architectural Drawings - JSC BevelClad - Bevel Back Weatherboards - Flexible Underlay 20mm Cavity Fix v2.6, 11/02/2026
  • f. Technical Drawings - JSC BevelClad - Bevel Back Weatherboard Cladding - 20mm Cavity on Rigid Underlay - v1.4 Dated 11/02/2026
  • g. Technical Drawings - JSC BevelClad - Bevel Back Weatherboard Cladding - 45mm Cavity on Flexible Underlay - v1.4 11/02/2026
  • h. Technical Drawings - JSC BevelClad - Bevel Back Weatherboard Cladding - 45mm Cavity on Rigid Underlay - v1.4 Dated 11/02/2026
  • i. JSC Exterior Timber Weatherboard Cladding, Maintenance Guide, Version 3.3, February 2026.

3. The System shall

  • a. be fixed over a ventilated cavity in conjunction with a flexible building underlay or rigid air barrier in accordance with the Applicable Technical Specification, and
  • b. be installed horizontally on vertical, flat surfaces, and
  • c. use the components and board profiles as described in the Applicable Technical Specification (where these components are substituted with alternative products, these applications fall outside the scope of this certification), and
  • d. incorporate joinery that meets the requirements of Section 4.4 of the Building Products Specifications for the relevant Wind Zone or wind pressure.

4. Stainless steel or silicon bronze fixings shall be used with TMT Amba, TMT Taiga RW, TMT Taiga WW, TMT Taxon, TMT Tuscan, TMT ThermoPine and TMT ThermoPine H3.2 MicroPro® treated, .

5. The designer shall provide a signed Declaration for submission with the building consent application that the use of this system in the proposed building work falls within the intended use of the system as described in this certificate and that all design conditions of this certificate have been met.

6. The installer shall supply a signed Declaration that the product has been installed in accordance with the installation conditions of this certificate, for consideration for issuing a Code Compliance Certificate (CCC).

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is not cited by any other resources.

JSC BevelClad Cladding System

This document is not CITED BY any other resources:

JSC BevelClad Cladding System

Description

Certificate holder: J.Scott and Company Limited, t/a JSC.

The JSC BevelClad Cladding System is an external wall cladding installed over a 20 mm or 45 mm ventilated cavity.

The BevelClad Cladding System (the System) comprises of horizontally fixed weatherboards installed over H3.2 treated timber cavity battens to form a either a 20 mm cavity or a 45 mm cavity, fascia boards and moulding profiles.

JSC BevelClad Cladding System weatherboards are manufactured from the following materials:

  • Western Red Cedar (Thuja Plicata)
  • Alaskan Yellow Cedar (Cupressus nootkatensis)
  • Radiata Pine – H3.2 (MicroPro® treated)
  • Nordic Pine - H3.2 (MicroPro® treated)
  • Iroko (Milicia excelsa)
  • TMT Amba
  • TMT Taiga RW
  • TMT Taiga WW
  • TMT Taxon
  • TMT Tuscan
  • TMT ThermoPine
  • TMT ThermoPine H3.2 MicroPro® treated.

View on Information Provider website
JSC BevelClad Cladding System
Description

Certificate holder: J.Scott and Company Limited, t/a JSC.

The JSC BevelClad Cladding System is an external wall cladding installed over a 20 mm or 45 mm ventilated cavity.

The BevelClad Cladding System (the System) comprises of horizontally fixed weatherboards installed over H3.2 treated timber cavity battens to form a either a 20 mm cavity or a 45 mm cavity, fascia boards and moulding profiles.

JSC BevelClad Cladding System weatherboards are manufactured from the following materials:

  • Western Red Cedar (Thuja Plicata)
  • Alaskan Yellow Cedar (Cupressus nootkatensis)
  • Radiata Pine – H3.2 (MicroPro® treated)
  • Nordic Pine - H3.2 (MicroPro® treated)
  • Iroko (Milicia excelsa)
  • TMT Amba
  • TMT Taiga RW
  • TMT Taiga WW
  • TMT Taxon
  • TMT Tuscan
  • TMT ThermoPine
  • TMT ThermoPine H3.2 MicroPro® treated.
View on Information Provider website
This resource does not cite any other resources.

JSC BevelClad Cladding System

This resource does not CITE any other resources.
Feedback