Thermakraft Covertek 405 Roof and Wall Underlay

Abbreviation
CMNZ30030 version: J
Version
J
Valid from
7/07/2025

Information provider
Ministry of Business, Innovation and Employment,
Author
Global-Mark Pty Ltd
Information type
Product Certificate (CodeMark),
Format
PDF,

Description

Thermakraft Covertek 405 Roof and Wall Underlay is an underlay for use under roof and wall claddings.

Thermakraft Covertek 405 Roof and Wall Underlay is a synthetic, fire retardant, absorbent, breathable building underlay for use under roof and wall claddings.

The product consists of a micro-porous water-resistant film laminated between two layers of non-woven spun-bonded polyolefin.

Thermakraft Covertek 405 Roof and Wall Underlay is coloured white on the top and bottom faces with yellow Covertek 405 branding on the exposed face.

Scope

1. Thermakraft Covertek 405 Roof and Wall Underlay use certified

  • a. as self-supporting roof underlay on buildings:
    • i. within the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and floor plan area; and,
    • ii. with
      • 1. masonry tile roof cladding; or,
      • 2. with metal tile roof cladding or
      • 3. profiled metal roof cladding; and,
    • iii. situated in NZS 3604-2011 and NASH Standard Part 2:2019 light steel framed buildings Wind Zones up to, and including Extra High.
    • iv. with a roof pitch of 3° and above
  • b. as flexible wall underlay for buildings:
    • i. within the scope limitations of
      • 1. NZBC Acceptable Solution E2/AS1, Paragraph 1.1 for timber-framed buildings; or,
      • 2. NASH Building Envelope Solutions: 2019-Light Steel Framed Buildings, Paragraph 1.1 for steel-framed buildings; and,
    • ii. with absorbent or non-absorbent wall claddings either direct fixed or installed over an 18 mm minimum drained cavity; or,
    • iii. with masonry veneer in accordance with
      • 1. NZBC Acceptable Solution E2/AS1 for timber-framed buildings or
      • 2. NASH Building Envelope Solutions for steel-framed buildings; and,
    • iv. situated in
      • 1. NZS 3604 and NASH Standard Part 2:2019 light steel framed buildings Wind Zones up to, and including, Very High; or,
      • 2. NZS 3604 and NASH Standard Part 2:2019 light steel framed buildings Wind Zones up to, and including, Extra High when used over a rigid wall underlay in accordance with NZBC Acceptable Solution E2/AS1 or NASH Building Envelope Solutions Paragraph 9.1.7.2.

2. Thermakraft Covertek 405 Roof and Wall Underlay shall be used and installed in accordance with all relevant technical information relating to the products use contained within Kingspan - Product data Sheet - Thermakraft Covertek 405 Self-supporting roof and wall underlay (Issue 8.0, May 2025) and Kingspan- Installation Guide - Thermakraft Covertek 405 Self-supporting roof and wall underlay (issue Issue 5.0, May 2025) and the BRANZ Appraisal No. 743 (2025) Amended 1 July 2025 Thermakraft Covertek 405 Roof and Wall Underlay (refer to www.branz.co.nz).

3. Thermakraft Covertek 405 Roof and Wall Underlay must not be exposed to the weather or ultraviolet light before being covered for a total of more than:

  • a. 7 days when used as a roof underlay
  • b. 60 days when used as a wall underlay.

4. Thermakraft Covertek 405 Roof and Wall Underlay must not be used in any unlined applications ((except in spaces without any permanent openings to allow entry of natural light e.g. attic spaces at gable ends), including but not limited to sheds, warehouses, garages, canopies, soffits and lean-to designs.

5. Thermakraft Covertek 405 Roof and Wall Underlay must be separated or protected from heat sources such as fireplaces, heating appliances, flues and chimneys.

6. When used as a roof underlay,

  • a. Thermakraft Covertek 405 Roof and Wall Underlay can be installed vertically or horizontally and must span no greater than 1200 mm in one direction between framing supports without additional underlay support. All underlay supports must be corrosion resistant material.
  • b. In addition, at roof pitch less than 10°, the underlay must be installed horizontally unless installed over a roof underlay support.

7. When used as a wall underlay, in cavity installations where the cavity battens are installed at greater than 450 mm centres, Thermakraft Covertek 405 Roof and Wall Underlay must be restrained between the battens to prevent the underlay bulging into the cavity space when bulk insulation is installed in the wall frame cavity.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is not cited by any other resources.

Thermakraft Covertek 405 Roof and Wall Underlay

This document is not CITED BY any other resources:

Thermakraft Covertek 405 Roof and Wall Underlay

Description

Thermakraft Covertek 405 Roof and Wall Underlay is an underlay for use under roof and wall claddings.

Thermakraft Covertek 405 Roof and Wall Underlay is a synthetic, fire retardant, absorbent, breathable building underlay for use under roof and wall claddings.

The product consists of a micro-porous water-resistant film laminated between two layers of non-woven spun-bonded polyolefin.

Thermakraft Covertek 405 Roof and Wall Underlay is coloured white on the top and bottom faces with yellow Covertek 405 branding on the exposed face.

View on Information Provider website
Thermakraft Covertek 405 Roof and Wall Underlay
Description

Thermakraft Covertek 405 Roof and Wall Underlay is an underlay for use under roof and wall claddings.

Thermakraft Covertek 405 Roof and Wall Underlay is a synthetic, fire retardant, absorbent, breathable building underlay for use under roof and wall claddings.

The product consists of a micro-porous water-resistant film laminated between two layers of non-woven spun-bonded polyolefin.

Thermakraft Covertek 405 Roof and Wall Underlay is coloured white on the top and bottom faces with yellow Covertek 405 branding on the exposed face.

View on Information Provider website
This resource does not cite any other resources.

Thermakraft Covertek 405 Roof and Wall Underlay

This resource does not CITE any other resources.
Feedback