BS EN 54-3:2001 Fire Detection And Fire Alarm Systems - Part 3: Fire Alarm Devices - Sounders

Abbreviation
BS EN 54-3:2001
Valid from
18/04/2001

Information provider
Standards New Zealand,
Author
British Standards Institution, European Standardization Organisations
Information type
European Standard,
Format
PDF, HARD COPY,


Description

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders in a fixed installation intended to signal an audible warning of fire between a fire detection and fire alarm system and the occupants of a building.

It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system.

This standard specifies fire alarm sounders for two types of application environment,

  • type A for indoor use and
  • type B for outdoor use.

This standard is not intended to cover:

  • loudspeaker type devices primarily intended for emitting emergency voice messages;
  • supervisory sounders, for example, within the control and indicating equipment.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

BS EN 54-3:2001 Fire Detection And Fire Alarm Systems - Part 3: Fire Alarm Devices - Sounders

This document is CITED BY:

BS EN 54-3:2001 Fire Detection And Fire Alarm Systems - Part 3: Fire Alarm Devices - Sounders

Description

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders in a fixed installation intended to signal an audible warning of fire between a fire detection and fire alarm system and the occupants of a building.

It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system.

This standard specifies fire alarm sounders for two types of application environment,

  • type A for indoor use and
  • type B for outdoor use.

This standard is not intended to cover:

  • loudspeaker type devices primarily intended for emitting emergency voice messages;
  • supervisory sounders, for example, within the control and indicating equipment.

View on Information Provider website
BS EN 54-3:2001 Fire Detection And Fire Alarm Systems - Part 3: Fire Alarm Devices - Sounders
Description

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders in a fixed installation intended to signal an audible warning of fire between a fire detection and fire alarm system and the occupants of a building.

It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system.

This standard specifies fire alarm sounders for two types of application environment,

  • type A for indoor use and
  • type B for outdoor use.

This standard is not intended to cover:

  • loudspeaker type devices primarily intended for emitting emergency voice messages;
  • supervisory sounders, for example, within the control and indicating equipment.