Air Admittance Valves (AAV's) consist of a one-way valve designed to allow air to enter the plumbing drainage system when a pressure less than atmospheric develops. The device closes and seals by gravity under zero (0) differential pressure (static condition) and under positive pressure. These devices prevent sewer gases from entering a building. The device consists of a hooded or shielded body which contains a movable sealing assembly which seats and seals air flow when closed and allows air to enter when open.

Temperature Range: These devices shall function at temperatures from -40.0°F to 150.0°F (-40.0°C to 65.6°C).

Rating: These devices shall, at a minimum, pass the required volume of air according to Table 1 at -1.0 inch (-25.4 mm) water column.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

ASSE 1050:2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems

This document is CITED BY:

ASSE 1050:2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems

Description

Air Admittance Valves (AAV's) consist of a one-way valve designed to allow air to enter the plumbing drainage system when a pressure less than atmospheric develops. The device closes and seals by gravity under zero (0) differential pressure (static condition) and under positive pressure. These devices prevent sewer gases from entering a building. The device consists of a hooded or shielded body which contains a movable sealing assembly which seats and seals air flow when closed and allows air to enter when open.

Temperature Range: These devices shall function at temperatures from -40.0°F to 150.0°F (-40.0°C to 65.6°C).

Rating: These devices shall, at a minimum, pass the required volume of air according to Table 1 at -1.0 inch (-25.4 mm) water column.

View on Information Provider website
ASSE 1050:2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
Description

Air Admittance Valves (AAV's) consist of a one-way valve designed to allow air to enter the plumbing drainage system when a pressure less than atmospheric develops. The device closes and seals by gravity under zero (0) differential pressure (static condition) and under positive pressure. These devices prevent sewer gases from entering a building. The device consists of a hooded or shielded body which contains a movable sealing assembly which seats and seals air flow when closed and allows air to enter when open.

Temperature Range: These devices shall function at temperatures from -40.0°F to 150.0°F (-40.0°C to 65.6°C).

Rating: These devices shall, at a minimum, pass the required volume of air according to Table 1 at -1.0 inch (-25.4 mm) water column.

View on Information Provider website
This resource cites:

ASSE 1050:2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems

This document CITES:
Feedback