AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
- Abbreviation
- AS/NZS 60898.1:2004
- Valid from
- 12/08/2004
- Information provider
- Standards New Zealand,
- Author
- Standards New Zealand, Standards Australia
- Information type
- New Zealand Standard,
- Format
- PDF, HARD COPY,
Description
This Standard provides essential safety and associated requirements for a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25,000 A. Annex ZZ lists variations for Australian and New Zealand conditions.
A modified adoption of IEC 60898-1:2003.
Scope
This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25000 A.
As far as possible, it is in line with the requirements contained in IEC 60947 -2.
These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained.
They are intended for use in an environment with pollution degree 2.
They are suitable for isolation.
Circuit-breakers of this standard, with exception of those rated 120 V or 120/240 V (see table 1), are suitable for use in IT systems provided that the requirements of IEC 60364-4-4-473:1977 and A1:1998 are complied with.
This standard also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool.
This standard does not apply to:
- - circuit-breakers intended to protect motors;
- - circuit-breakers, the current setting of which is adjustable by means accessible to the user.
For circuit-breakers having a degree of protection higher than IP20 according to IEC 60529, for use in locations where arduous environmental conditions prevail (e.g. excessive humidity, heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur), special constructions may be required.
Requirements for circuit-breakers for a.c. and d.c. operation are giver in IEC 60898-2.
Requirements for circuit-breakers which incorporate residual current tripping devices are to be found in IEC 61009-1, IEC 62009-2-1 and IEC 61009-2-2.
A guide for co-ordination under short-circuit conditions between a circuit-breaker and another short-circuit protective device (SCPDs) is given in annex D.
This resource is cited by:
AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation
This document is CITED BY:
-
AS/NZS 3000:2007
AS/NZS 60898.1:2004 is cited by AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
-
AS/NZS 3000:2018
AS/NZS 60898.1:2004 is cited by AS/NZS 3000:2018 Electrical installations - Known as the Australian/New Zealand Wiring Rules