AS 1012.12.1-1998 (R2014) Methods of testing concrete. Method 12: Determination of mass per unit volume of hardened concrete - Part 1: Rapid measuring method
- Abbreviation
- AS 1012.12.1-1998 (R2014)
- Version
- Reconfirmed 24/10/2014
- Valid from
- 5/09/1998
- Information provider
- Intertek Inform,
- Author
- Standards Australia
- Information type
- Australian Standard,
- Format
- PDF, HARD COPY,
Description
This Standard sets out a rapid method for determining the mass per unit volume of hardened concrete consisting of regular shaped specimens with a minimum of defects.
Scope
This Method is also applicable to capped specimens, provided the mass per unit volume of the cap does not differ from that of the specimen by more than 25 percent.
NOTES:
- Because of possible variation in results, it is envisaged that the mass per unit volume of concrete should be based on the average value determined from a group of at least two representative specimens.
- For general procedures and precautions designed to promote safety of persons and property in laboratory operations (see AS/NZS 2243.1 - list in Referenced Documents).
- This Standard may involve hazardous materials, operations, and equipment. This Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
This resource is cited by:
AS 1012.12.1-1998 (R2014) Methods of testing concrete. Method 12: Determination of mass per unit volume of hardened concrete - Part 1: Rapid measuring method
This document is CITED BY:
-
AS/NZS 2327:2017
AS 1012.12.1-1998 (R2014) is cited by AS/NZS 2327:2017 Composite structures - Composite steel-concrete construction in buildings