Watertight Wall Underlay
- Abbreviation
- Appraisal number 939 (2023)
- Valid from
- 6/04/2023
- Information provider
- BRANZ Limited,
- Information type
- BRANZ Appraisal,
- Format
- PDF,
Description
Watertight Wall Underlay is a synthetic wall underlay for use as a flexible wall underlay under wall claddings on timber and steel-framed buildings.
The product consists of a micro-porous, waterresistant polypropylene film laminated between two layers of spun-bonded polypropylene and is coloured grey.
Scope
Flexible Wall Underlay
Watertight Wall Underlay has been appraised for use as a flexible wall underlay for timber and steel-framed buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 for timber-framed buildings, or;
- the scope limitations of NASH Building Envelope Solutions, Paragraph 1.1 for steel-framed buildings; and,
- with direct fixed absorbent and non-absorbent wall claddings; or,
- with absorbent and non-absorbent wall claddings installed over an 18 mm minimum drained cavity; or,
- with masonry veneer in accordance with NZBC Acceptable Solution E2/AS1 for timber-framed buildings or to NASH Building Envelope Solutions Paragraph 1.1 for steel-framed buildings; and,
- situated in NZS 3604 Wind Zones up to and including Very High.
Use over Rigid Wall Underlay
Watertight Wall Underlay has been appraised for use as a flexible wall underlay over rigid wall underlays on timber and steel-framed buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 for timber-framed buildings, or;
- the scope limitations of NASH Building Envelope Solutions, Paragraph 1.1 for steel-framed buildings; and,
- with absorbent and non-absorbent wall claddings installed over an 18 mm minimum drained cavity; and,
- with masonry veneer in accordance with NZBC Acceptable Solution E2/AS1 for timber-framed buildings or NASH Building Envelope Solutions for steel-framed buildings; and,
- situated with NZS 3604 and NASH Standard Part 2 Wind Zones up to, and including, Extra High.
Specific Design
Watertight Wall Underlay has also been appraised for use on buildings subject to specific weathertightness design. Building designers are responsible for the building design and for the incorporation of Watertight Wall Underlay into their design in accordance with the declared properties and the instructions of Techno Wrapping Systems Limited.