Viking Post-Applied Tanking Membranes
- Abbreviation
- Appraisal number 864 (2025)
- Amendment
- 17/06/2026
- Valid from
- 18/06/2025
- Information provider
- BRANZ Limited,
- Information type
- BRANZ Appraisal,
- Format
- PDF,
Description
Viking Post-Applied Tanking Membranes is a torch-on, post-applied tanking membrane for basement retaining walls and floors where subsoil drainage is provided.
Viking Underslab membranes, installed as pre-applied membranes beneath concrete floor slabs, form a supplementary component to the system, providing continuity of waterproofing at the floor and wall interface with Viking Post-Applied Tanking Membranes.
Scope
1. Viking Post-Applied Tanking Membranes have been appraised as post-applied membranes for use:
- on buildings subject to non-specific design under floor slabs complying with NZS 3604 and behind concrete masonry basement walls and under floor slabs complying with NZS 4229; and,
- on buildings subject to specific design with substrates of insitu or precast concrete complying with NZS 3101 or concrete masonry complying with NZS 4230; and,
- where subsoil drainage and free draining granular backfill has been placed behind basement walls.
2. Viking Post-Applied Tanking Membranes must be adequately protected against damage during
backfilling and in service.
3. The membranes must be installed by Viking Roofspec Ltd approved installers.