Innova™ Stratum™ Contour Cavity Cladding System
- Abbreviation
- Appraisal number 848 (2019)
- Amendment
- A3 - 31/10/2024
- Valid from
- 23/05/2019
- Information provider
- BRANZ Limited,
- Information type
- BRANZ Appraisal,
- Format
- PDF,
Description
The Innova™ Stratum™ Contour Cavity Cladding System is a cavity-based, external wall cladding system. It is designed to be used as external wall cladding system for residential and light commercial type buildings where domestic construction techniques are used.
The Innova™ Stratum™ Contour Cavity Cladding System consists of Innova™ Stratum™ Contour fibre cement planks fixed over structural timber battens to form a cavity. The fibre cement planks are finished with an acrylic paint system.
Scope
1. The Innova™ Stratum™ Contour Cavity Cladding System has been appraised as an external wall cladding system for buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,
- constructed with timber framing complying with the NZBC; and,
- with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/AS1, Table 2; and
- situated in NZS 3604 Wind Zones up to, and including Extra High.
2. The Innova™ Stratum™ Contour Cavity Cladding System has also been appraised for weathertightness and structural wind loading when used as an external wall cladding system for buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regard to building height and floor plan area; and,
- constructed with timber framing complying with the NZBC; and,
- situated in specific design wind pressures up to a maximum design differential ultimate limit state (ULS) of 2.5 kPa.
3. The Innova™ Stratum™ Contour Cavity Cladding System must only be installed horizontally on vertical surfaces.
4. The Innova™ Stratum™ Contour Cavity Cladding System has been appraised for use with aluminium window and door joinery that is installed with vertical jambs and horizontal heads and sills. (Note: The Appraisal of the Innova™ Stratum™ Contour Cavity Cladding System relies on the joinery meeting the requirements of NZS 4211 for the relevant Wind Zone or wind pressure.)