Shadowclad® Ventilated Cavity Cladding System
- Abbreviation
- Appraisal number 764 (2023)
- Valid from
- 29/11/2023
- Information provider
- BRANZ Limited,
- Information type
- BRANZ Appraisal,
- Format
- PDF,
Description
Shadowclad® Ventilated Cavity is a cavity-based external wall cladding system for residential and light commercial type buildings where domestic construction techniques are used.
The system consists of Shadowclad® sheets, timber cavity battens, flashings and accessories and is finished with either an acrylic paint system or penetrating or film-forming stain.
Shadowclad® Ventilated Cavity incorporates a primary and secondary means of weather resistance (first and second line of defence) against water penetration by separating the cladding from the external wall frame with a nominal 20 mm drained cavity.
Scope
Shadowclad® Ventilated Cavity has been appraised as an external wall cladding for buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,
- constructed with timber framing complying with the NZBC; and,
- with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/AS1, Table 2; and,
- situated in NZS 3604 Wind Zones up to, and including Extra High', and,
- with a building height of ≤10 m and at a distance of ≥1 m to the relevant boundary.
Shadowclad® Ventilated Cavity has also been appraised as an external wall cladding for specifically designed buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,
- constructed with timber framing complying with the NZBC; and,
- situated in specific design wind pressures up to a maximum design differential ultimate limit state (ULS) of 2.5 kPa; and,
- with a building height of ≤10 m and at a distance of ≥1 m to the relevant boundary.
Shadowclad® Ventilated Cavity is appraised for use with aluminium window and door joinery that is installed with vertical jambs and horizontal heads and sills. (The Appraisal of Shadowclad® Ventilated Cavity relies on the joinery meeting the requirements of NZS 4211 for the relevant Wind Zone or wind pressure.)