StoTherm Masonry Insulation System
- Abbreviation
- Appraisal number 604 (2024)
- Valid from
- 17/09/2024
- Information provider
- BRANZ Limited,
- Information type
- BRANZ Appraisal,
- Format
- PDF,
Description
The StoTherm Masonry Insulation System is an exterior insulation and finishing system for concrete masonry, in-situ or pre-cast concrete walls.
The system consists of expanded polystyrene (EPS) insulation panels fixed to the concrete masonry or concrete wall with adhesive mortar and mechanical anchors. The insulation panels are finished with either the StoArmat Miral Render System or the StoMiral Render System. The StoArmat Miral Render System is a fibreglass mesh-reinforced, synthetic resin solid render system. The Sto Miral Render System is a fibreglass mesh-reinforced, mineral, solid render system. The render systems are finished with a Sto coating.
Scope
1. The StoTherm Masonry Insulation System has been appraised as an exterior insulation and finishing system for buildings within the following scope:
- with substrates of concrete masonry, in-situ or pre-cast concrete, up to 3 storeys, with a maximum height from ground to eaves of 10 m; and,
- with floor plan area limited only by seismic and structural control joints; and,
- with supporting structures designed and constructed in accordance with the NZBC; and,
- situated in NZS 3604 Wind Zones up to, and including, Extra High.
2. The StoTherm Masonry Insulation System has also been appraised for bond/fixing, durability and weathertightness of the exterior insulation and finishing system for concrete masonry, in-situ or pre-cast concrete buildings subject to specific design up to a differential design ultimate limit state (ULS) wind pressure of 2.5 kPa.
3. The StoTherm Masonry Insulation System must only be applied on vertical surfaces except for sills, concrete reinforced parapets and concrete reinforced balustrades, which must have a minimum 10° slope and be waterproofed in accordance with the requirements of the Technical Literature and building designer.
4. The StoTherm Masonry Insulation System for use on buildings within the scope detailed in Paragraph 2.1 is appraised for use with aluminium window and door joinery that is installed with vertical jambs and horizontal heads and sills. (Note: The Appraisal of the StoTherm Masonry Insulation System relies on the joinery meeting the requirements of NZS 4211 for the relevant Wind Zone.)
5. Installation of renders and accessories supplied by Stoanz Limited and Sto registered contractors must be carried out only by Sto registered contractors.