AS/NZS 60695.11.5:2005 Fire hazard testing. Part 11.5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

Abbreviation
AS/NZS 60695.11.5:2005
Valid from
24/11/2005

Information provider
Standards New Zealand,
Author
Standards Australia, Standards New Zealand, International Electrotechnical Commission
Information type
New Zealand Standard,
Format
PDF, HARD COPY,


Description

This standard specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials.

This Standard is identical to and is reproduced from IEC 60695-11-5 Ed 1.

Scope

This Standard is identical to and is reproduced from IEC 60695-11-5 Ed 1 Test flames – Needle flame test method – Apparatus, confirmatory test arrangement and guidance.

Annex A and Annex B are for information only.

Clause 2 has been reformatted to indicate the Australia/New Zealand standard that is equivalent to the IEC standard or ISO standard to which normative reference is made.

The bibliography has been reformatted to indicate the Australia/New Zealand standard that is equivalent to the IEC standard or ISO standard to which an informative reference is made. As this Standard is reproduced from an International Standard, the following applies:

  • a) Its number does not appear on each page of text and its identity is shown on the cover and title page only.
  • b) In the source text "IEC 60695" should read "AS/NZS 60695".
  • c) A full point substitutes for a comma when referring to a decimal marker.

 

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

AS/NZS 60695.11.5:2005 Fire hazard testing. Part 11.5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

This document is CITED BY:

AS/NZS 60695.11.5:2005 Fire hazard testing. Part 11.5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

Description

This standard specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials.

This Standard is identical to and is reproduced from IEC 60695-11-5 Ed 1.

View on Information Provider website
AS/NZS 60695.11.5:2005 Fire hazard testing. Part 11.5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
Description

This standard specifies a needle-flame test to simulate the effect of a small flame which may result from fault conditions, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating materials or other combustible materials.

This Standard is identical to and is reproduced from IEC 60695-11-5 Ed 1.

View on Information Provider website
This resource does not cite any other resources.

AS/NZS 60695.11.5:2005 Fire hazard testing. Part 11.5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance

This resource does not CITE any other resources.
Feedback