Description

IEC 61249-4-1:2008 gives requirements for properties of prepreg that is mainly intended to be used as bonding sheets in connection with laminates according to IEC 61249-2-7 when manufacturing multilayer boards in line with IEC 62326-4. This material may be also used to bond other types of laminates. Prepreg according to this standard is of defined flammability (vertical burning test).

The flammability rating on fully cured prepreg is achieved through the use of brominated fire retardants contained as an integral part of the polymeric structure. After lamination according to the supplier's instructions, the glass transition temperature is defined as being 120 °C minimum.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

IEC 61249-4-1:2008 Materials for printed boards and other interconnecting structures - Part 4-1: Sectional specification set for prepreg materials, unclad (for the manufacture of multilayer boards) - Epoxide woven E-glass prepreg of defined flammability

This document is CITED BY:

IEC 61249-4-1:2008 Materials for printed boards and other interconnecting structures - Part 4-1: Sectional specification set for prepreg materials, unclad (for the manufacture of multilayer boards) - Epoxide woven E-glass prepreg of defined flammability

Description

IEC 61249-4-1:2008 gives requirements for properties of prepreg that is mainly intended to be used as bonding sheets in connection with laminates according to IEC 61249-2-7 when manufacturing multilayer boards in line with IEC 62326-4. This material may be also used to bond other types of laminates. Prepreg according to this standard is of defined flammability (vertical burning test).

The flammability rating on fully cured prepreg is achieved through the use of brominated fire retardants contained as an integral part of the polymeric structure. After lamination according to the supplier's instructions, the glass transition temperature is defined as being 120 °C minimum.

View on Information Provider website
IEC 61249-4-1:2008 Materials for printed boards and other interconnecting structures - Part 4-1: Sectional specification set for prepreg materials, unclad (for the manufacture of multilayer boards) - Epoxide woven E-glass prepreg of defined flammability
Description

IEC 61249-4-1:2008 gives requirements for properties of prepreg that is mainly intended to be used as bonding sheets in connection with laminates according to IEC 61249-2-7 when manufacturing multilayer boards in line with IEC 62326-4. This material may be also used to bond other types of laminates. Prepreg according to this standard is of defined flammability (vertical burning test).

The flammability rating on fully cured prepreg is achieved through the use of brominated fire retardants contained as an integral part of the polymeric structure. After lamination according to the supplier's instructions, the glass transition temperature is defined as being 120 °C minimum.