ASTM E2189 - 10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units

Abbreviation
ASTM E2189 - 10e1
Valid from
1/11/2010

Information provider
American Society of Testing and Materials
Author
American Society of Testing and Materials
Information type
ASTM Standard
Format
PDF


Description

This test method covers procedures for testing the performance of preassembled permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open.

Scope

This test method covers procedures for testing the resistance to fogging of preassembled permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open.

This test method is applicable only to sealed insulating glass units that are constructed with glass.

This test method is applicable to both double-glazed and triple-glazed insulating glass units; for triple-glazed insulating glass units where both of the outer lites are glass and the inner lite is either glass or a suspended film.

The unit construction used in this test method contains construction details that are essential components of the test. Different types of glass, different glass thicknesses and different airspace sizes may affect the test results.

This test method is not applicable to sealed insulating glass units containing a spandrel glass coating due to testing limitations.

The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

ASTM E2189 - 10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units

This document is CITED BY:

ASTM E2189 - 10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units

Description

This test method covers procedures for testing the performance of preassembled permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open.

View on Information Provider website
ASTM E2189 - 10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units
Description

This test method covers procedures for testing the performance of preassembled permanently sealed insulating glass units or insulating glass units with capillary tubes intentionally left open.

View on Information Provider website
This resource does not cite any other resources.

ASTM E2189 - 10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units

This resource does not CITE any other resources.
Feedback