AS 2360.1.1-1993 Measurement of fluid flow in closed conduits - Part 1.1: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm

Abbreviation
AS 2360.1.1-1993
Valid from
20/12/1993

Information provider
Intertek Inform
Author
Standards Australia
Information type
Australian Standard
Format
PDF, HARD COPY


Description

This part of AS 2360.1.1 specifies the geometry and method of use (installation and operating conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. It also gives necessary information for calculating the flow-rate and its associated uncertainty.

It is identical with and has been reproduced from ISO 5167-1:1991.

Scope

This Standard applies only to pressure differential devices in which the flow remains subsonic throughout the measuring section and is steady or varies only slowly with time and where the fluid can be considered as single-phase. In addition, each of these devices can only be used within specified limits of pipe size and Reynolds number.

Thus this part of AS 2360.1.1 cannot be used for pipe sizes less than 50 mm or more than 1200 mm or for pipe Reynolds numbers below 3150.

It deals with devices for which direct calibration experiments have been made, sufficient in number, spread and quality to enable coherent systems of application to be based on their results and coefficients to be given with certain predictable limits of uncertainty.

The devices introduced into the pipe are called "primary devices". The term primary device also includes the pressure tappings. All other instruments or devices required for the measurement are known as "secondary devices". This part of AS 2360.1.1 covers primary devices; secondary devices will be mentioned only occasionally.

The different primary devices dealt with in this part of AS 2360.1.1 are as follows:

  • a) orifice plates, which can be used with corner pressure tappings, D and D/2 pressure tappings, and flange pressure tappings;
  • b) ISA 1932 nozzles, and long radius nozzles, which differ in shape and in the position of the pressure tappings;
  • c) classical Venturi tubes, and Venturi nozzles, which differ in shape and in the position of the pressure tappings.
For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

AS 2360.1.1-1993 Measurement of fluid flow in closed conduits - Part 1.1: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm

This document is CITED BY:

AS 2360.1.1-1993 Measurement of fluid flow in closed conduits - Part 1.1: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm

Description

This part of AS 2360.1.1 specifies the geometry and method of use (installation and operating conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. It also gives necessary information for calculating the flow-rate and its associated uncertainty.

It is identical with and has been reproduced from ISO 5167-1:1991.

View on Information Provider website
AS 2360.1.1-1993 Measurement of fluid flow in closed conduits - Part 1.1: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm
Description

This part of AS 2360.1.1 specifies the geometry and method of use (installation and operating conditions) of orifice plates, nozzles and Venturi tubes when they are inserted in a conduit running full to determine the flow-rate of the fluid flowing in the conduit. It also gives necessary information for calculating the flow-rate and its associated uncertainty.

It is identical with and has been reproduced from ISO 5167-1:1991.

View on Information Provider website
This resource does not cite any other resources.

AS 2360.1.1-1993 Measurement of fluid flow in closed conduits - Part 1.1: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi tubes - Conduits with diameters from 50 mm to 1200 mm

This resource does not CITE any other resources.
Feedback