2018/007: Compliance of door thresholds to a proposed gymnasium in a school
- Abbreviation
- 2018/007
- Valid from
- 19/03/2018
- Information provider
- Ministry of Business, Innovation and Employment
- Information type
- Determination
- Format
Description
This determination considered the compliance of door thresholds to a proposed gymnasium in a school where the threshold incorporated a change in level of 20mm between the external and internal surfaces.
The determination assessed the detail against the Acceptable Solutions D1/AS1, C/AS4 and E2/AS1 and discussed the terms “stepped threshold”, “weather stop” and “isolated step”.