FM APPROVAL ANSI 4880:2007 Evaluating: a) insulated wall or wall &roof/ceiling assemblies, b) plastic exterior building panels, d) wall/ceiling coating systems, e) interior or exterior finish systems

Abbreviation
FM APPROVAL ANSI 4880:2007
Version
Includes all amendments and changes through Reaffirmation Notice, 2007
Valid from
1/01/2007

Information provider
IHS Markit
Author
FM Approvals LLC (FM)
Information type
Other Standard
Format
HARD COPY


Description

This standard states Approval requirements for insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems for use where a Class 1 fire rating is needed in wall or wall and roof/ceiling constructions. 

Approval criteria may include, but are not limited to, performance requirements, marking requirements, examination of manufacturing facility(ies), audit of quality assurance procedures, and a follow-up program.

Scope

This standard sets the fire performance requirements for Class 1 fire rated insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems in wall or wall and roof/ceiling constructions installed to maximum heights of 30 or 50 ft (9.1 or 15.2 m) or without height restriction when exposed to an ignition source simulating a building fire. If building use, occupancy or furnishings are combustible and can be expected to sustain a fire, installation of an automatic sprinkler system is recommended. 

The performance of insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems depends in part on the fasteners, adhesives or other accessories used in their installation and the substrate over which they are installed. It is therefore necessary to evaluate all of the components of the construction and include them in the constructions tested. 

This standard evaluates insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems for their performance in regard to fire. Roof panels and other roofing materials covered by this standard shall also meet the combustibility from above the roof assembly and wind uplift, foot traffic, hail and water leakage resistance requirements of FM Approvals Standard 4470 — Class 1 Roof Covers or FM Approvals Standard 4471 — Class 1 Metal Panel Roofs. Exterior wall panels and exterior wall systems covered by this standard shall also meet the windload and impact resistance requirements of FM Approvals Standard 4881 - Class 1 Exterior Wall Systems. Interior wall and ceiling materials or systems covered by this standard used in smoke sensitive occupancies shall also meet the requirements of FM Approvals Standard 4882 — Class 1 Interior Wall and Ceiling Materials or Systems for Smoke Sensitive Occupancies. Insulated walls shall have the option to be evaluated using FM Approvals Standard 4411 — Insulated Wall Constructions. 

This standard is intended to evaluate only those hazards investigated, and is not intended to determine suitability for the end use of a product. 

The results of tests conducted under the controlled conditions required by this standard shall not be used to describe or appraise performance under actual fire conditions. Actual fire conditions vary widely. 

This standard shall not qualify exterior insulated finish systems (EIFS) or other exterior wall coating systems. 

For assistance with locating previous versions, please contact the information provider.
Notes/comments

NZS 4541:2007 cites FM Approval 4880:2005, which is not currently available online. We have provided you with a link to this more recent version for your information only. 

View on Information Provider website
For assistance with locating previous versions, please contact the information provider.

NZS 4541:2007 cites FM Approval 4880:2005, which is not currently available online. We have provided you with a link to this more recent version for your information only. 

This resource is cited by:

FM APPROVAL ANSI 4880:2007 Evaluating: a) insulated wall or wall &roof/ceiling assemblies, b) plastic exterior building panels, d) wall/ceiling coating systems, e) interior or exterior finish systems

This document is CITED BY:

FM APPROVAL ANSI 4880:2007 Evaluating: a) insulated wall or wall &roof/ceiling assemblies, b) plastic exterior building panels, d) wall/ceiling coating systems, e) interior or exterior finish systems

Description

This standard states Approval requirements for insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems for use where a Class 1 fire rating is needed in wall or wall and roof/ceiling constructions. 

Approval criteria may include, but are not limited to, performance requirements, marking requirements, examination of manufacturing facility(ies), audit of quality assurance procedures, and a follow-up program.

View on Information Provider website
FM APPROVAL ANSI 4880:2007 Evaluating: a) insulated wall or wall &roof/ceiling assemblies, b) plastic exterior building panels, d) wall/ceiling coating systems, e) interior or exterior finish systems
Description

This standard states Approval requirements for insulated wall or wall and roof/ceiling panels, interior finish materials or coatings and exterior wall systems for use where a Class 1 fire rating is needed in wall or wall and roof/ceiling constructions. 

Approval criteria may include, but are not limited to, performance requirements, marking requirements, examination of manufacturing facility(ies), audit of quality assurance procedures, and a follow-up program.

View on Information Provider website
This resource does not cite any other resources.

FM APPROVAL ANSI 4880:2007 Evaluating: a) insulated wall or wall &roof/ceiling assemblies, b) plastic exterior building panels, d) wall/ceiling coating systems, e) interior or exterior finish systems

This resource does not CITE any other resources.
Feedback