FM APPROVAL 4880:2015 Class 1 Fire Rating of Building Panels or Interior Finish Materials

Abbreviation
FM APPROVAL 4880:2015
Valid from
1/10/2015

Information provider
GlobalSpec
Author
FM Approvals (Factory Mutual Laboratories)
Information type
Other Standard
Format
PDF


Description

This standard states the test requirements for building panels or interior finish materials for interior applications where a Class 1 fire rating is needed for wall and/or ceiling constructions.

This standard sets the fire performance requirements for a Class 1 fire rating of building panel assemblies or interior finish materials with specific height installation requirements and combustibility ratings.

Scope

Building panels or interior finish materials shall be tested for installations:

  • with a maximum height restriction of 30 ft (9.1 m),
  • with a maximum height restriction of 50 ft (15.2 m), or
  • without height restrictions (i.e. unlimited height).

The combustibility of a core insulation or interior finish materials shall be identified as combustible or non-combustible.

Building panels or interior finish materials include, but are not limited to:

  • Insulated or non-insulated wall and/or ceiling panels with an inert or non-inert facer and combustible core or noncombustible core; and
  • Interior finish materials:
    • thermoplastic panels,
    • thermoset panels, and
    • coatings systems and exposed interior insulations.

Any component which may be used in the installation of a building panel or interior finish material such as, fasteners, adhesives, sealants, flashing, substrates, or any other accessories, is considered part of the scope of the product and must be evaluated in conjunction with the product. Any component that may affect the test performance must be included in the test sample construction.

This standard evaluates building panels or interior finish materials for an interior installation application only.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

FM APPROVAL 4880:2015 Class 1 Fire Rating of Building Panels or Interior Finish Materials

This document is CITED BY:

FM APPROVAL 4880:2015 Class 1 Fire Rating of Building Panels or Interior Finish Materials

Description

This standard states the test requirements for building panels or interior finish materials for interior applications where a Class 1 fire rating is needed for wall and/or ceiling constructions.

This standard sets the fire performance requirements for a Class 1 fire rating of building panel assemblies or interior finish materials with specific height installation requirements and combustibility ratings.

View on Information Provider website
FM APPROVAL 4880:2015 Class 1 Fire Rating of Building Panels or Interior Finish Materials
Description

This standard states the test requirements for building panels or interior finish materials for interior applications where a Class 1 fire rating is needed for wall and/or ceiling constructions.

This standard sets the fire performance requirements for a Class 1 fire rating of building panel assemblies or interior finish materials with specific height installation requirements and combustibility ratings.

View on Information Provider website
This resource does not cite any other resources.

FM APPROVAL 4880:2015 Class 1 Fire Rating of Building Panels or Interior Finish Materials

This resource does not CITE any other resources.
Feedback