AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings

Abbreviation
AS 1668.1:2015
Amendment
Amendment 1 - incorporated.
Valid from
14/12/2015

Information provider
Intertek Inform
Author
Standards Australia
Information type
Australian Standard
Format
PDF, HARD COPY


Description

This Standard sets out minimum requirements for the design, construction, installation and commissioning of mechanical smoke control systems in buildings.

Specific methods of smoke control are defined and the appropriate requirements specified for each.

Scope

The design information given in this Standard in respect to hot layer smoke control is based on a single axisymmetric plume, which is confined to on reservoir. Smoke plumes spilling across multiple reservoirs are not considered.

Requirements for the maintenance of smoke control systems are not included.

This Standard applies to Class 2 to Class 9 buildings where smoke control is required.

The Standard doesn't identify those buildings in which smoke control systems or pressurization systems are required. 

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings

This document is CITED BY:

AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings

Description

This Standard sets out minimum requirements for the design, construction, installation and commissioning of mechanical smoke control systems in buildings.

Specific methods of smoke control are defined and the appropriate requirements specified for each.

View on Information Provider website
AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings
Description

This Standard sets out minimum requirements for the design, construction, installation and commissioning of mechanical smoke control systems in buildings.

Specific methods of smoke control are defined and the appropriate requirements specified for each.

View on Information Provider website
This resource cites:

AS 1668.1:2015 The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings

This document CITES:
New Zealand Standards
Australian Standards
Other
Feedback