SikaRoof MTC Roof and Deck Membrane
- Abbreviation
- Appraisal number 670
- Valid from
- 17/01/2018
- Information provider
- BRANZ Limited
- Information type
- BRANZ Appraisal
- Format
Description
SikaRoof MTC Roof and Deck Membrane is a UV resistant, aliphatic polyurethane based, liquid-applied waterproofing membrane for roofs and decks.
Scope
SikaRoof MTC Roof and Deck Membrane has been appraised as a roof and deck waterproofing membrane on buildings within the following scope:
- the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; or,
- the scope of limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards to building height and floor plan area when subject to specific structural design; and,
- with substrates of plywood or suspended concrete slab; and,
- with minimum falls for roofs of 1:30 and decks of 1:40; and,
- with deck size limited to 40 m²; and,
- situated in NZS 3604 Wind Zones, up to, and including Extra High.
SikaRoof MTC Roof and Deck Membrane has also been appraised as a roof and deck waterproofing membrane on buildings within the following scope:
- subject to specific structural and weathertightness design; and,
- with substrates of plywood or suspended concrete slab; and,
- situated in specific design wind pressures up to a maximum design differential ultimate limit state (ULS) of 6 kPa; and,
- with the weathertightness design of junctions for each specific structure being the responsibility of the building designer.
Roofs and decks waterproofed with SikaRoof MTC Roof and Deck Membrane must be designed and constructed in accordance with the following limitations:
- decks and nominally flat or pitched roofs constructed to drain water to gutters and drainage outlets complying with the NZBC; and,
- with no steps within the deck level, no integral roof gardens and no downpipe direct discharge to the deck; and,
- with the deck membranes continually protected from physical damage by a pedestal protection system.
The design and construction of the substrate and movement and control joints is specific to each building, and therefore is the responsibility of the building designer and building contractor and is outside the scope of the Appraisal.
The membrane must be installed by trained applicators, approved by Sika (NZ) Ltd.