2018/020:The refusal to issue a code compliance certificate for a 9-year old house with rammed-earth walls
- Abbreviation
- 2018/020
- Valid from
- 17/05/2018
- Information provider
- Ministry of Business, Innovation and Employment
- Information type
- Determination
- Format
Description
This determination considers the compliance of the second stage of a house built with rammed-earth walls used as a structural element and as a cladding. The determination considers the compliance of the as-built work, the on-going maintenance of the rammed-earth walls, and whether the authority was correct in declining to issue a code compliance certificate for the work.