Acceptable Solution G12/AS2: Solar Water Heaters
- Abbreviation
- G12/AS2
- Amendment
- 8
- Version
- Third Edition, Amendment 8
- Valid to
- 14/08/2014
- Valid from
- 10/10/2011
This resource is no longer current. The current versions are G12/AS2 (Amd 12) (Third Edition, Amendment 12), G12/AS2 (Amd 13) (Third Edition, Amendment 13)
- Information provider
- Ministry of Business, Innovation and Employment
- Information type
- Acceptable Solution
- Format
Description
Acceptable Solution G12/AS2 provides a means of compliance with Building Code Clause G12 Water Supplies for solar water heaters. G12 requires the safe supply, storage, reticulation and delivery of hot and cold water.
It requires buildings provided with water outlets, sanitary fixtures or sanitary appliances to have safe and adequate water supplies (including where hot water is necessary). It sets out requirements to avoid scalding, injury, leaks, contamination, illness and the prevention of legionella growth.
Scope
This Acceptable Solution applies to solar water heaters installed in or on buildings.
This resource is not cited by any other resources.
Acceptable Solution G12/AS2: Solar Water Heaters
This document is not CITED BY any other resources:
This resource cites:
Acceptable Solution G12/AS2: Solar Water Heaters
This document CITES:
New Zealand Standards
-
AS/NZS 1170.0:2002
G12/AS2 cites AS/NZS 1170.0:2002 Structural Design Actions - General principles from 1/12/2007
-
AS/NZS 1170.1:2002
G12/AS2 cites AS/NZS 1170.1:2002 (R2016) Structural Design Actions - Permanent, imposed and other actions from 1/12/2007
-
AS/NZS 1170.2:2002
G12/AS2 cites AS/NZS 1170.2:2002 Structural Design Actions - Wind Actions from 23/06/2007
-
AS/NZS 1170.3:2003 (Reconfirmed in 2016)
G12/AS2 cites AS/NZS 1170.3:2003 (R2016) Structural Design Actions - Snow and ice actions from 1/12/2007
-
AS/NZS 2712:2002
G12/AS2 cites AS/NZS 2712:2002 Solar and heat pump water heaters - Design and construction from 1/12/2007 until 1/07/2009
-
AS/NZS 2712:2007
G12/AS2 cites AS/NZS 2712:2007 Solar and heat pump water heaters - Design and construction from 1/12/2007
-
AS/NZS 3500.4:2003
G12/AS2 cites AS/NZS 3500.4:2003 Plumbing and drainage - Part 4: Heated water services from 1/12/2007
-
AS/NZS 4692.2:2005
G12/AS2 cites AS/NZS 4692.2:2005 (R2016) Electric water heaters - Minimum Energy Performance Standards (MEPS) requirements and energy labelling from 1/12/2007
-
NZS 1170.5:2004 (Excl. A1)
G12/AS2 cites NZS 1170.5:2004 (Excl. A1) Structural Design Actions - Part 5: Earthquake design actions - New Zealand - Sponsored. from 1/12/2007
-
NZS 3604:1990
G12/AS2 cites NZS 3604:1990 Code of practice for light timber frame buildings not requiring specific design - SPONSORED from 1/12/2007
-
NZS 3604:1999
G12/AS2 cites NZS 3604:1999 Timber framed buildings - SPONSORED from 1/12/2007
-
NZS 3604:2011
G12/AS2 cites NZS 3604:2011 Timber-framed buildings - SPONSORED from 10/10/2011
-
NZS 4203:1992
G12/AS2 cites NZS 4203:1992 General structural design and design loadings for buildings - SPONSORED from 1/12/2007
-
NZS 4613:1986
G12/AS2 cites NZS 4613:1986 Domestic solar water heaters - SPONSORED from 1/12/2007
-
NZS 4614:1986
G12/AS2 cites NZS 4614:1986 Installation of domestic solar water heating systems - SPONSORED from 1/12/2007