ASTM E104-02 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions

Abbreviation
ASTM E104-02
Valid from
1/01/2002

Information provider
American Society of Testing and Materials
Author
American Society of Testing and Materials
Information type
ASTM Standard
Format
PDF


Description

This practice describes one method for generating constant relative humidity (rh) environments in relatively small containers. It is applicable for obtaining constant relative humidities ranging from dryness to near saturation at temperatures spanning from 0 to 50 degreesC.

Scope

1.1 This practice describes one method for generating constant relative humidity (rh) environments in relatively small containers.

1.2 This practice is applicable for obtaining constant relative humidities ranging from dryness to near saturation at temperatures spanning from 0 to 50 degreesC.

1.3 This practice is applicable for closed systems such as environmental conditioning containers and for the calibration of hygrometers.

1.4 This practice is not recommended for the generation of continuous (flowing) streams of constant humidity unless precautionary criteria are followed to ensure source stability.

1.5 Caution-Saturated salt solutions are extremely corrosive, and care should be taken in their preparation and handling. There is also the possibility of corrosive vapors in the atmospheres over the saturated salt solutions.

1.6 This Standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

ASTM E104-02 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions

This document is CITED BY:

ASTM E104-02 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions

Description

This practice describes one method for generating constant relative humidity (rh) environments in relatively small containers. It is applicable for obtaining constant relative humidities ranging from dryness to near saturation at temperatures spanning from 0 to 50 degreesC.

View on Information Provider website
ASTM E104-02 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions
Description

This practice describes one method for generating constant relative humidity (rh) environments in relatively small containers. It is applicable for obtaining constant relative humidities ranging from dryness to near saturation at temperatures spanning from 0 to 50 degreesC.

View on Information Provider website
This resource cites:

ASTM E104-02 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions

This document CITES:
Other
Feedback