AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Part 2.15: Particular requirements for isolating transformers for the supply of medical locations

Abbreviation
AS/NZS 61558.2.15:2001
Valid from
11/11/2001

Information provider
Standards New Zealand
Author
Standards New Zealand, Standards Australia
Information type
New Zealand Standard
Format
PDF, HARD COPY


Description

This Standard specifies general safety requirements for approval and test purposes for isolating transformers for the supply of medical locations.

This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-15:1999.

Scope

This Standard deals with all aspects of safety such as electrical, thermal and mechanical.

This part 2-15 of AS/NZS 61558 applies to stationary, single-phase or polyphase, air-cooled (natural or forced) isolating transformers used to provide an IT supply system for the supply of cardiac-protected electrical areas. The no-load output voltage and the rated output voltage shall not exceed 250 V a.c. single-phase or polyphase (phase-to-phase voltage). Isolating transformers are used where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification.

This standard is applicable to dry-type transformers. The winding may be encapsulated or non-encapsulated.

This standard also applies to transformers incorporating electronic circuits.

This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.

For assistance with locating previous versions, please contact the information provider.
View on Information Provider website
For assistance with locating previous versions, please contact the information provider.
This resource is cited by:

AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Part 2.15: Particular requirements for isolating transformers for the supply of medical locations

This document is CITED BY:

AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Part 2.15: Particular requirements for isolating transformers for the supply of medical locations

Description

This Standard specifies general safety requirements for approval and test purposes for isolating transformers for the supply of medical locations.

This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-15:1999.

View on Information Provider website
AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Part 2.15: Particular requirements for isolating transformers for the supply of medical locations
Description

This Standard specifies general safety requirements for approval and test purposes for isolating transformers for the supply of medical locations.

This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-15:1999.

View on Information Provider website
This resource does not cite any other resources.

AS/NZS 61558.2.15:2001 Safety of power transformers, power supply units and similar - Part 2.15: Particular requirements for isolating transformers for the supply of medical locations

This resource does not CITE any other resources.